A.2 Approvals for USA, Canada and Australia

The characters stamped on a device are indicative of the requirements which that
device meets:
Underwriters Laboratories (UL) to the UL 1950 standard, Report E11 5352
Underwriters Laboratories (UL) to the Canadian standard C22.2 No. 950
C
UL recognition mark
Canadian Standard Association (CSA) to standard C22.2 No. 950 or C22.2 No. 220,
Canadian Standard Association (CSA) to standard C22.2 No. 950 or C22.2 No. 220,
Report LR 81690
FM
FM approval to Factory Mutual Approval Standard Class Number 3611, Class I, Division 2,
Group A, B, C, D
APPROVED
Note for Australia
Our product fulfills the requirements for Norm AS/NZS 3548.

FM Approval Notes

FM approval, if present, is to Factory Mutual Approval Standard Class Number
3611, Class I, Division 2, Group A, B, C, D.
Temperature class T5 is adhered to when the ambient temperature during
operation does not exceed 60 C.
Warning
!
Personal injury or property damage can result.
In hazardous areas, personal injury or property damage can result if you close or
disconnect an electrical circuit during operation (e.g. plug-in connections, fuses,
switches).
Do not close or disconnect any live circuits unless explosion hazards can be
definitely excluded.
Warning
!
WARNING - DO NOT DISCONNECT WHILE CIRCUIT IS LIVE
UNLESS LOCATION IS KNOWN TO BE NON-HAZARDOUS
SIMATIC TD 200 Operator Interface
C79000-G7076-C272-01
Specifications and Reference
A-3