3-2. Rotary Switch

Make sure to test the operation of the F3SG-R after setting with Rotary Switch to verify that the
F3SG-R operates as intended. Make sure to stop the machine until the test is complete.
Unintended settings may cause a person to go undetected, resulting in serious injury or death.
F3SG-R series has the Rotary Switches to configure functions near the power cable. Configure functions with
the Rotary Switches before installing F3SG-R in your site. Make sure to turn the power of the F3SG-R on after
the setting with the Rotary Switches is complete.
Cascaded sensors are operated based on the Rotary Switches setting of the primary sensor. The Rotary
Switch setting of a secondary sensor does not affect the operation.
For F3SG-R series, the following functional settings are available by the Rotary Switch on the emitter and
receiver.
Function
Scan Code Selection
- Operate the Rotary Switches before turning the power of the F3SG-R on.
- Both the emitter and receiver units must be set to the same code.
- A change of the Rotary Switches setting is activated upon power-on or lockout reset.
- If the Rotary Switch is operated during operation of the F3SG-R, the F3SG-R transitions to lockout.
Position
Code A
(factory default setting)
Rotary Switch
Code B
Rotary Switch
Setting with Rotary Switch and End Cap
Description
Refer to
2-3
2-3
F3SG-4RA-25-02TS
E
29