Checklists

6-2. Maintenance Checklists

Perform daily and 6-month inspection for the F3SG-R. Otherwise, the system may fail to work
properly, resulting in serious injury.
Do not try to disassemble, repair, or modify this product. Doing so may cause the safety functions
to stop working properly.
To ensure safety, keep a record of the inspection results.
When the user is a different person from those who installed or designed the system, he/she must be properly
trained for maintenance.
6-2-1. Checklists

6-2-1-1. Inspection at Startup and When Changing Operators

There is no approach route other than through the detection zone of the F3SG-R.
Part of the operator's body always remains in the detection zone of the F3SG-R when working around
the machine's hazardous part.
The actual safety distance is equal to or greater than the calculated value.
There must be no dirt on or damage to the optical surface of the F3SG-R.
When 24 V Active is enabled, ON/OFF indicator turns red when the TEST line is short-circuited to 9
V to Vs. When 0 V Active is enabled, ON/OFF indicator turns red when the TEST line is short-circuited
to 0 to 3 V.
The test rod is not deformed.
The test rod is detected when it is moved around in the detection zone as shown in the diagram below.
In other words, when a test rod is inserted into the detection zone, the Stable-state indicator turns
OFF and the ON/OFF indicator turns red.
When fixed blanking function is used, you must ensure that all blanked zones in the detection zone
are covered by a hard barrier guard and there must be no zone in the detection zone where the test
rod goes undetected.
Neither connector, cap, or bracket must be loose.
F3SG-4RA-25-02TS
90
User's Manual
Start
Stop
Test rod