NB!:
If Not active [0] is selected, the motor can-
not be stopped by means of the [STOP]-key.
015 Local jog
015
(LOCAL JOGGING)
Value:
Not active (DISABLE)
Active (ENABLE)
Function:
In this parameter, the jog function on the LCP con-
trol panel can be engaged/disengaged.
Description of choice:
If Not active [0] is selected in this parameter, the
[JOG]-key will be inactive.
016 Local reversing
016
(LOCAL REVERSING)
Value:
Not active (DISABLE)
Active (ENABLE)
Function:
In this parameter you can select/deselect the revers-
ing function on the LCP control panel. The key can
only be used if parameter 002 Local/remote opera-
tion is set to Local operation [1] and parameter 013
Localcontrol to Local control, open loop [1] or Local
control as parameter 100 [3].
Description of choice:
If Disable [0] is selected in this parameter, the [FWD/
REV] key will be disabled. See also parameter 200
Output frequency range.
017 Local reset of trip
017
(LOCAL RESET)
Value:
Not active (DISABLE)
Active (ENABLE)
Function:
In this parameter, the reset function on the control
panel can be engaged/disengaged.
Description of choice:
If Not active [0] is selected in this parameter, the re-
set function will be inactive.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.28.A5.02 - VLT is a registered Danfoss trade mark
®
VLT
2800 Series
NB!:
Select Not active [0], only if an external reset
signal has been connected via the digital in-
puts.
018 Lock for data changes
018
(DATA CHANGE LOCK)
[0]
Value:
[1]
Not locked (NOT LOCKED)
Locked (LOCKED)
Function:
In this parameter, it is possible to 'lock' the controls
to disable data changes via the control keys.
Description of choice:
If Locked [1] is selected, data changes in the param-
eters cannot be made; however, it will still be
possible to make data changes via serial communi-
cation. Parameter 009-012 Display readout can be
changed via the control panel.
[0]
[1]
019 Operating mode at power-up, local opera-
019
tion
(POWER UP ACTION)
Value:
Auto restart, use saved reference (AUTO
RESTART)
Forced stop, use saved reference
(LOCAL=STOP)
Forced stop, set ref. to 0
(LOCAL=STOP , REF=0)
Function:
Setting of the required operating mode when the
mains voltage is engaged. This function can only be
active if Local operation [1] has been selected in pa-
rameter 002 Local/remote operation.
Description of choice:
Auto restart, use saved ref. [0] is selected if the fre-
quency converter is to start using the local reference
[0]
(set in parameter 003 Local reference) and the start/
[1]
stop state given via the control keys immediately
prior to the mains voltage being cut out.
Forced stop, use saved ref. [1] is selected if the fre-
quency converter is to remain stopped when the
mains voltage is engaged, until the [START]-key is
activated. After a start command the motor speed is
ramped up to the saved reference in parameter 003
Local reference.
Forced stop, set ref. to 0 [2] is selected if the fre-
quency converter is to remain stopped when the
[0]
[1]
[0]
[1]
[2]
13