Specifications
Digital output
Programmable digital/pulse outputs
Terminal number
Voltage level at digital/frequency output
Maximum output current (sink or source)
Maximum load at frequency output
Maximum capacitive load at frequency output
Minimum output frequency at frequency output
Maximum output frequency at frequency output
Accuracy of frequency output
Resolution of frequency outputs
1) Terminal 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Pulse inputs
Programmable pulse inputs
Terminal number pulse
Maximum frequency at terminal 29, 33
Maximum frequency at terminal 29, 33
Minimum frequency at terminal 29, 33
Voltage level
Maximum voltage on input
Input resistance, R
i
Pulse input accuracy (0.1–1 kHz)
Control card, 24 V DC output
Terminal number
Maximum load
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
Relay outputs
Programmable relay outputs
Relay 01 terminal number
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Relay 02 terminal number
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Minimum terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO)
Environment according to EN 60664-1
1) IEC 60947 parts 4 and 5.
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
2) Overvoltage category II.
3) UL applications 300 V AC 2 A.
MG20MD02
Operating Guide
1)
on 1-3 (NC), 1-2 (NO) (resistive load)
(inductive load @ cosφ 0.4)
1)
1)
on 1-2 (NO), 1-3 (NC) (resistive load)
1)
(inductive load)
1)
on 4-5 (NO) (resistive load)
2) 3)
on 4-5 (NO) (inductive load @ cosφ 0.4)
1)
1)
on 4-5 (NO) (resistive load)
1)
on 4-5 (NO) (inductive load)
1)
on 4-6 (NC) (resistive load)
on 4-6 (NC) (inductive load @ cosφ 0.4)
1)
1)
on 4-6 (NC) (resistive load)
1)
on 4-6 (NC) (inductive load)
Danfoss A/S © 10/2016 All rights reserved.
Maximum error 0.1% of full scale
110 kHz (push-pull driven)
5 kHz (open collector)
See Digital inputs
Approximately 4 kΩ
Maximum error 0.1% of full scale
1-3 (break), 1-2 (make)
240 V AC, 0.2 A
24 V DC, 0.1 A
4-6 (break), 4-5 (make)
240 V AC, 0.2 A
24 V DC, 0.1 A
240 V AC, 0.2 A
24 V DC, 0.1 A
24 V DC, 10 mA, 24 V AC, 20 mA
Overvoltage category III/pollution degree 2
2
1)
27, 29
0–24 V
40 mA
1 kΩ
10 nF
0 Hz
32 kHz
12 bit
2
29, 33
4 Hz
8
8
28 V DC
12, 13
200 mA
2
240 V AC, 2 A
60 V DC, 1 A
400 V AC, 2 A
80 V DC, 2 A
240 V AC, 2 A
50 V DC, 2 A