Configuring The Lora Network Server - Multitech MultiConnect Conduit Getting Started Manual

Base station ip67
Table of Contents

Advertisement

5.
Restart and test your connection.
Stop Automatic Start Up
To stop ppp from automatically starting, issue:
$ update-rc.d -f ppp remove

Configuring the LoRa Network Server

Note:
This section applies to LoRaWAN V1.5 devices only.
To configure the LoRa Network Server:
1.
Install the LoRa mCard. Refer to
conduit-platform/accessory-cards/installing-an-accessory-card/.
2.
Attach the LoRa antenna to the LoRa mCard.
3.
Use the power cable to connect power to the Conduit and wait for the Conduit to boot up.
4.
Log in to the console. Refer to
with-conduit-mlinux/
5.
Issue these commands on the Conduit:
$ cp /opt/lora/lora-network-server.conf.sample /var/config/lora/lora-
network-server.conf
6.
Edit /var/config/lora/lora-network-server.conf and modify these settings as needed (use vi or nano).
Field
lora["frequencyBand"]:
lora["channelplan"]:
lora["frequencySubBand"]:
lora["frequencyEU"]:
network["name"]
network["passphrase"]
network["public"]
7.
Restart the network server.
$ /etc/init.d/lora-network-server restart
8.
Start mosquitto client.
$ mosquitto_sub -t lora/+/+ -v
For advanced LoRa settings, go to
communication/conduit-mlinux-advance-lora-configuration/.
®
TM
MultiConnect
Conduit
http://www.multitech.net/developer/software/mlinux/getting-started-
if needed.
MTAC-LoRa-915 (NA & AU)
"915"
"US915 or "AU915"
(integer. 1 to 8)
Not Applicable
Name of your LoRa network (string, 8-character minimum, case-sensitive).
Security passphrase for your LoRa network (string, 8-character minimum,
case-sensitive).
Enable to use public SyncWord (0x34) and join window of 5 and 6 seconds.
http://www.multitech.net/developer/software/lora/conduit-mlinux-lora-
Base Station IP67 Getting Started Guide for Versions 1.5 and 2.1
http://www.multitech.net/developer/products/multiconnect-
GETTING STARTED WITH MLINUX MODELS
MTAC LoRa-868 (EU)
"868"
"EU868"
Not applicable
default 869500000
range: [863500000 - 867500000] and
869100000 - 869500000]