Aqua Stop Valve - Bosch SRS4002GB Repair Instruction

Table of Contents

Advertisement

4.3

Aqua Stop valve

The valve system consists of two valves in series, which are actuated
electrically parallel, and the filler valve and safety valve. The safety
function may be actuated via the safety level chamber or electrically
via the float in the base pan. The water flow is then stopped
mechanically. An electric solenoid valve which is enclosed by
a housing is attached to the tap. The housing is connected to the base
pan by a leakage water hose (sleeve of the inlet hose). The water inlet
hose, which connects the valve to the water inlet, and the electrical
control line for the solenoid valve are located inside this leakage water
hose.
Technical specifications:
Nominal voltage
Frequency
Resistance
Flow rate
Water pressure
58300000002393_ara_en_a.doc – 31.07.07
230–240 V
50 Hz
2 kΩ
2.75 l/min
0.5–10 bar
A
= Solenoid valves
B
= Control cable
C
= Inlet hose
D
= Leakage-water hose
Seite 21 von 60