Setting the vertical tracking force (VTF)
Place counterweight halfway along the counterweight support rod, being sure to have the locking screw
uppermost. With the power of and platter static, place the stylus pressure gauge onto the platter. To set the
required VTF place the tip of the stylus on the pressure gauge. Moving the counterweight towards the
cartridge will reduce VTF and away will increase VTF. In order to avoid the damage oh the cartridge be sure
that all time all the cartridges movements must be done in upper tonearm lift position. Repeat the measuring
procedure until you get the correct VTF.
Adjust the VTF prior to installing the anti-skating weight.
For adjustment and control of vertical tracking force (VTF) is supplied in the package electronic stylus
balance Pro-Ject Meaure IT II
Please note: It is advised to remove stylus tip from gauge or fit stylus protection whilst making
adjustments to avoid damage to stylus.
Product information:
Case made of aluminium
4 digit LCD-Display with backlight
Capacity 0-5g
Variance ± 0,002g
Auto calibration function
Auto off after 60 seconds
Batteries supplied (teo AAA cells)
Dimensions (W x H x D) 122 x 25 x 55mm
Weight 170g
Adjusting the vertical tracking angle (VTA)
Put a record on the platter. When the needle is lowered into the record groove and the tonearm is not resting
on the tonearm rest, the tube of the tonearm should be parallel to the surface of the record. If it is not,
loosen both VTA adjustment screws in the tonearm base just enough to allow vertical movement of the arm
pillar without force and slide the arm up or down until it is parallel. Carefully retighten VTA adjustment
screws without applying excessive force which would deform the arm pillar.