Valves Maintenance - Devatec ElectroVap ELMC 1 SM CYL Technical Manual

Electrode steam humidifier electrovap mc2 series
Hide thumbs Also See for ElectroVap ELMC 1 SM CYL:
Table of Contents

Advertisement

Maintenance - Valves
INLET VALVE MAINTENANCE
1
E
V
LECTRO
AP
The inlet valve should be maintained every 6 months as a
minimum and after 50 hours operation.
Isolate the water supply and remove the water supply hose from the
valve.
Disconnect the electrical wires from the coil.
Untighten the collar clamp and remove the water feed hose.
Unscrew the black nut 1 and lay it on the cylinder compartment tray.
Take the valve out and remove the basket filter from the base of the
valve with a pair of long nose pliers. Pull the coil out with a flat screw
driver.
Wash the basket filter under clean water to remove any dirt and debris.
Replace whole valve if cleaning is not practical or replace coil if
necessary.
Assemble in reverse order taking care to replace collar clamp if
necessary.
Ensure that everything is correctly assembled and switch the humidifier
on.
Ensure that all the clamps are properly tightened whenever
the humidifier is maintained.
57
MC2
Pictures for illustrating purposes only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents