Troubleshooting Guide (cont.)
Error
Problem
Code
Unable to
-
connect to the
manifold with
-
the remote
-
-
System does
21
not maintain/
reach ride
height
-
Compressor
22
runs often
without
commanding an
inflate
adjustment
Cause
Wireless controller batteries are low
Blown 15A fuse
Weak Bluetooth signal
Wireless controller has become
unpaired from the manifold
Large leak in the system
The vehicle could be
overloaded
Small air leak in the system
Solution
Check wireless controller battery icon. Change batteries if
necessary (See page 20)
Check 15A fuse. Enter the pairing screen on the remote or
the devices menu on the mobile app and see if the manifold
is visible via Bluetooth
Ensure the manifold is mounted forward of the rear axle.
Move manifold to a location that is not shielded by metal
Re-pair the remote by removing and re-inserting the 15A
fuse. The manifold will be in pairing mode for 3 minutes after
power is applied
Locate and correct leak (See Finding Air Leaks and Fixing
Leaks in Barbed Fittings and Fixing Leaks on PTC Fittings).
Remove and reinstall the 15A fuse to reset the fault
If the air pressure in the system is at its max pressure of 100
PSI (7BAR), the system will stop inflating.
Locate and correct leak (See Finding Air Leaks and Fixing
Leaks in Barbed Fittings and Fixing Leaks on PTC Fittings
and Fixing Leaks on Braided Stainless Steel Air Lines)