WirelessONE User Guide
Troubleshooting Guide (cont.)
Error
Problem
Code
If the ignition wire is not connected, the system will only maintain a preset when the vehicle starts moving or is
connected to the wireless controller or mobile app.
Compressor
1
doesn't run
when inflation is
2
commanded
3
4
15
18
19
-
Cause
Vehicle battery voltage is too low
(below 9 volts)
Vehicle battery voltage is too high
(above 18 volts)
Manifold temperature is too cold
Manifold temperature is too hot
Compressor over-current
Compressor duty cycle limit has been
reached
Blockage in the compressor or
system which is preventing air flow
Bad ground, poor wire connections,
bad compressor or bad manifold
Solution
Check the vehicle battery
Check the vehicle battery and charging system
Allow manifold to warm up
Allow manifold to cool down. Move manifold to location that
is not near heat sources
Use the mobile app to clear the error code. Disconnect the
compressor and test on the bench using 12 volts
Allow the compressor to sit idle until the cool down
period (15 minutes) has been reached
Check for system blockages or frozen moisture in the air
lines. Remove and reinstall the 15A fuse to reset the fault
Disconnect the compressor and test on the bench using
12 volts