Plumbing Requirements

For integrated models with an automatic ice maker, the
water supply line should be located through the floor or
back wall, within the shaded area shown in the illustra-
tions. The water supply line should be connected to the
house supply with an easily accessible shut-off valve
between the supply and the unit. Do not use self-piercing
valves. A saddle valve kit (4200880) is avail able through
your authorized Sub-Zero dealer.
IMPORTANT NOTE: It is critical that the water line be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket.
An in-line filter is required when water conditions have a
high sediment content. The ice maker operates on
constant water pressure between 1.4 bar and 6.9 bar.
IMPORTANT NOTE: In some cases, a reverse osmosis
water filter system may not be able to maintain the
minimum pressure consistently.