Teledyne Falcon4 86M User Manual page 59

Hide thumbs Also See for Falcon4 86M:
Table of Contents

Advertisement

AutoBrightness
autoBrightnessOffsetY
OffsetY
AutoBrightness
autoBrightnessOffsetX
OffsetX
AutoBrightness
autoBrightnessHeight
Height
AutoBrightness
autoBrightnessWidth
Width
Flatfield
flatfieldCorrectionAlgorithm
Calibration
Algorithm
Falcon4 86M Cameras
Sets the start of the area in the y direction
for pixels included in the color PRNU
Target average.(RW)
Is automatically increased if the OffsetY is
increased and has minimum value
OffsetY+2. This parameter increments in
multiples of 2
The autoBrightnessHeight may need to be
reduced before this value can be
increased.
autoBrightnessOffsetY <= OffsetY+Height
-4-autoBrightnessHeight.
Sets the start of the area in the x direction
for pixels included in the color PRNU
Target average.(RW)
Has minimum value 0 and increments in
multiples of 32. Non multiples of 32 are
rounded down to the nearest multiple.
The autoBrightnessWidth may need to be
reduced to increase this value. The
minimum width is 64.
autoBrightnessOffsetX <= 10720-
autoBrightnessWidth.
Determines the number of rows to include
in the average used to set the PRNU
targets for color sensors.(RW)
The minimum autoBrightnessHeight is 4
rows and the maximum is Height-4. The
autoBrightnessheight is increased in
multiples of 2 and if an odd number is
entered, the entry will be rounded down
when possible. Also the
AutoBrightnessOffsetY may need to be
decreased before increasing this
parameter.
autoBrighitnessHeight =<OffsetY+Height-
2-autoBrightnessOffsetY
Determines the number of columns to
include in the average used to set the
PRNU targets for color sensors.(RW)
The minimum autoBrightnessWidth is 64
columns and the maximum is Width is
10720. The width is increased in multiples
of 32 and entries will be rounded down to a
multiple of 32. Also the
AutoBrightnessOffsetX may need to be
decreased before increasing this
parameter.
autoBrighitnessWidth <= 10720 -
autoBrightnessOffsetx
Selects the algorithm to use for calibration
of flat field PRNU coefficients. (RW)
DFNC
Beginner
Contents  57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa-s0-86m16-01-rFa-s1-86m16-00-r