Goulds Pumps 3700 Installation, Operation And Maintenance Manual page 64

Table of Contents

Advertisement

Maintenance
2. Slide the cartridge mechanical seal away from the seal-chamber cover.
3. Install the eyebolt in the tapped hole provided in the seal-chamber cover.
4. Rig the lifting sling to the eyebolt and the overhead lifting device.
5. Loosen and remove the seal-chamber cover and the bearing frame bolts.
6. Separate the seal-chamber cover from the bearing frame by tapping on the cover flange
with a hardwood block or a soft-face hammer.
122
184
228
355
360Q
370H
7. Guide the seal-chamber cover over the end of the shaft once the cover releases from the
bearing frame.
NOTICE:
The cartridge mechanical seal may become damaged if the cover is allowed to come in
contact with it.
8. Loosen the setscrews and remove the cartridge mechanical seal from the shaft.
62
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Shaft
Seal-chamber cover
Bearing frame
Gland stud nuts
Gland gasket
Bearing frame bolts
Manual