If your pump is...
SX, MX, LA, LX, XLA, or
XLX
SA and MA
11. Remove any remaining plugs and fittings.
Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance
Manual
Then...
1. Loosen and remove the radial-bearing end cover and bearing-
frame screws.
2. Remove and discard the radial-bearing end-cover gasket. You will
replace this with a new gasket during reassembly.
3. Press the radial and thrust deflector out of the radial and thrust end
covers.
If you have an optional radial heat flinger, it replaces the standard
radial deflector and is removed in the same manner except you loosen
three set screws.
119A
123
228
360
370P
Remove the radial-bearing end cover and radial deflector with gasket
or radial deflector from the bearing frame by tapping it out of the frame.
If you have an optional radial heat flinger, it replaces the standard
radial deflector and is removed in the same manner except you loosen
three set screws.
Thrust end cover
Deflector
Bearing frame
Radial-bearing end-cover gasket
Bearing-frame screws
Maintenance