1.1 INSTALLATION
RECOMMENDATIONS.
e Victrix Tera Plus boiler has been designed
for wall mounted installation only; for central
heating and production of domestic hot water
(when the boiler is connected to an external storage
tank unit) for domestic use and similar purposes.
e place of installation of the appliance and
relative Immergas accessories must have suitable
features (technical and structural), such as to al-
low for (always in safe, e cient and comfortable
conditions):
- installation (according to the provisions of
technical legislation and technical regulations);
- maintenance operations (including scheduled,
periodic, routine, special);
- removal (to outdoors in the place for loading
and transporting the appliances and com-
ponents) as well as the eventual replacement
of those with appliances and/or equivalent
components.
e wall surface must be smooth, without any
protrusions or recesses enabling access to the
rear part.
ey are not designed to be installed
on plinths or oors (Fig. 1).
By varying the type of installation the classi ca-
tion of the boiler also varies, precisely:
- Type B
or B
boiler if installed using the
23
53
relevant terminal for air intake directly from
the room in which the boiler has been installed.
- Type C boiler if installed using concentric
pipes or other types of pipes envisioned for
the sealed chamber boiler for intake of air and
expulsion of ue gas.
Only professionally enabled companies are
authorised to install Immergas gas appliances.
Installation must be carried out according to
regulation standards, current legislation and in
compliance with local technical regulations and
the required technical procedures.
Important: the manufacturer declines all liability
for damages caused by boilers removed from
other systems or for any non-conformities of
such equipment.
Before installing the appliance, ensure that it is
delivered in perfect condition; if in doubt, contact
the supplier immediately. Packing materials (sta-
ples, nails, plastic bags, polystyrene foam, etc.)
constitute a hazard and must be kept out of the
reach of children. If the appliance is installed in-
side or between cabinets, ensure su cient space
for normal servicing; therefore it is advisable to
leave clearance of at least 3 cm between the boiler
casing and the vertical sides of the cabinet. Leave
adequate space above the boiler for possible water
and ue removal connections. Keep all amma-
ble objects away from the appliance (paper, rags,
plastic, polystyrene, etc.).
Do not place household appliances underneath
the boiler as they could be damaged if the safety
valve intervenes, if the drain trap is blocked, or
if there are leaks from the hydraulic connec-
tions; otherwise, the manufacturer cannot be
held responsible for any damage caused to the
household appliances.
For the aforementioned reasons, we recommend
not placing furnishings, furniture, etc. under
the boiler.
In the event of malfunctions, faults or incorrect
operation, turn the appliance o immediately
and contact an authorised company (e.g. the
Immergas Technical Assistance centre, which
has speci cally trained sta and original spare
parts). Do not attempt to modify or repair the
appliance alone.
Failure to comply with the above implies personal
responsibility and invalidates the warranty.
• Installation Standards:
- this boiler can be installed outdoors in a
partially protected area. A partially protected
area is one in which the boiler is not exposed
to the direct action of the weather (rain, snow,
hail, etc..).
is type of installation is only possible when
permitted by the laws in force in the appliance's
country of destination.
- Installation of gas appliances, ue exhaust
pipes and combustion air intake pipes is
forbidden in places with a re risk (for ex-
ample: garages, closed parking stalls), and
in potentially dangerous places.
- Installation is prohibited on the vertical
projection of the cooking surface.
- Installation is forbidden in places/rooms
that constitute public areas of apartment
buildings, internal stairways or other escape
routes (e.g. oor landings, entrance halls,
etc.).
- Installation is also forbidden in places/rooms
that constitute public areas of apartment
buildings such as cellars, entrance halls, attics,
lo s, etc., unless otherwise provided for by
local regulations in force.
Attention: installing the wall recessed frame
kit must guarantee the boiler stable, e cient
support.
e recessed frame kit ensures ap-
propriate support only if installed correctly
(according to the rules of good practice),
following the instructions on its instructions
lea et.
e recessed frame for the boiler is not
a supporting structure and must not replace
the wall removed. It is necessary to position
the boiler inside the wall. For safety reasons
against any leaks it is necessary to plaster the
boiler housing in the brick wall.
5
NO
YES
SI
NO
Attention: wall mounting of the boiler must
guarantee stable and e cient support for the
generator.
e plugs (standard supply) are only to be used
to x the boiler to the wall; they only ensure
adequate support if inserted correctly (according
to technical standards) in walls made of solid or
semi-hollow brick or block. In the case of walls
made from hollow brick or block, partitions with
limited static properties, or in any case walls
other than those indicated, a static test must be
carried out to ensure adequate mount.
ese boilers are used to heat water to below
boiling temperature in atmospheric pressure.
ey must be connected to a central heating
system and domestic hot water circuit suited to
their performance and capacity.
Attention: the storage tank unit must also be
installed in an environment in which the tem-
perature cannot fall below 0°C.
"Anti-legionella" heat treatment of the storage
tank (activated by the speci c function present
on the predisposed thermoregulation systems):
during this stage, the temperature of the water
inside the storage tank exceeds 60°C with a
relative risk of burns. Keep this domestic hot
water treatment under control (and inform
the users) to prevent unforeseeable damage
to people, animals, things. If required install a
thermostatic valve on the domestic hot water
outlet to prevent scalding.