HEAT
HEAT
POWER
POWER
(kW)
(kcal/h)
28,3
24295
27,5
23650
D.H.W.
26,5
22790
25,5
21930
24,1
20717
23,5
20210
22,5
19350
21,5
18490
20,5
17630
19,5
16770
18,5
15910
17,5
15050
16,5
14190
15,5
13330
CEN. HEAT.
14,5
12470
13,5
11610
D.H.W.
12,5
10750
11,5
9890
10,5
9030
9,5
8170
8,5
7310
7,5
6450
6,5
5590
5,5
4730
4,5
3870
4,3
3689

3.23 VARIABLE HEAT OUTPUT.

N.B.: the power data in the table has been ob-
tained with intake-exhaust pipe measuring 0.5 m
METHANE (G20)
MODULA-
GAS FLOW RATE BURNER
TION
(%)
99
97
93
89
85
81
78
74
70
66
62
58
54
50
45
+
41
37
33
29
24
20
16
11
7
2
1
in length. Gas ow rates refer to net heating value
below a temperature of 15°C and at a pressure
of 1013 mbar.
MODULA-
TION
(m
3
/h)
(%)
3,06
99
2,98
97
2,87
93
2,76
88
2,61
82
2,54
80
2,44
76
2,33
72
2,22
68
2,11
64
2,01
60
1,90
56
1,79
52
1,68
48
1,58
43
1,47
39
1,36
35
1,26
31
1,15
27
1,04
23
0,93
19
0,82
15
0,72
11
0,61
6
0,50
2
0,48
1
43
PROPANE (G31)
GAS FLOW RATE BURNER
(kg/h)
2,25
2,19
2,11
2,03
1,91
1,87
1,79
1,71
1,63
1,55
1,47
1,39
1,31
1,24
1,16
1,08
1,00
0,92
0,84
0,76
0,68
0,61
0,53
0,45
0,37
0,35

Hide quick links: