1.13 OUTDOOR INSTALLATION IN
PARTIALLY PROTECTED AREA.
N.B.: a partially protected location is one in which
the appliance is not exposed to the direct action of
the weather (rain, snow, hail, etc..)..
• Con guration type B, open chamber and fan
assisted.
Using the special coverage kit one can achieve
direct air intake (Fig. 12) and ue gas exhaust
in a single chimney or directly outside. In this
con guration it is possible to install the boiler in
a partially protected place. In this con guration
the boiler is classi ed as type B.
With this con guration:
- air intake takes place directly from the envi-
ronment in which the appliance is installed
(external);
- the ue gas exhaust must be connected to its
own single ue (B
) or ducted directly outside
23
via a vertical terminal for direct exhaust (B
or via an Immergas ducting system (B
The technical regulations in force must be
respected.
• Coverage kit assembly (Fig. 13). Remove the
two plugs from the lateral intake holes. Now
cover the le intake hole using the relevant
plate, xing it onto the right side using the 2
previously-removed screws. Install the Ø 80
outlet ange on the central hole of the boiler,
taking care to insert the gasket supplied with
the kit and tighten by means of the screws
provided. Install the upper cover, xing it using
the 4 screws present in the kit, positioning the
relevant gaskets. Engage the 90° Ø 80 bend
with the male end (smooth) in the female end
(with lip seal) of the Ø 80 ange unit until
it stops. Introduce the gasket, making it run
along the bend. Fix it using the metal sheet
plate and tighten by means of the clips present
in the kit, making sure to block the 4 gasket
aps. Fit the male end (smooth) of the exhaust
terminal into the female end of the bend 90° Ø
80, making sure that the relevant wall sealing
plate is already tted; this will ensure hold and
joining of the elements making up the kit.
e cover kit includes:
N° 1
Heat moulded cover
N°1
Gasket clamping plate
N°1
Gasket
N°1
Gasket clamp
N°1
N°1 Intake hole covering plate
e terminal kit includes:
N° 1 Gasket
N° 1 Exhaust ange Ø 80
N° 1 Bend 90° 80 Ø
N° 1 Exhaust pipe Ø 80
N° 1 Wall sealing plate
Max. length of exhaust duct.
vertical or horizontal) can be extended to a max.
length of 30 linear metres.
• Coupling of extension pipes. To install
push- tting extensions with other elements
of the ue, proceed as follows: Install the pipe
or elbow with the male side (smooth) in the
female section (with lip seal) to the stop on the
previously installed element.
sealing e ciency of the coupling.
• Con guration without cover kit in a partially
protected location (type C boiler)
N.B.: a partially protected location is one in
which the appliance is not exposed to the direct
action of the weather (rain, snow, hail, etc..)..
By leaving the side plugs tted it is possible
to install the appliance externally without the
cover kit. Installation takes place using the
Ø60/100 and Ø 80/125 concentric intake/
)
exhaust kits. Refer to the paragraph on indoor
53
).
installation. In this con guration the upper
53
cover kit guarantees additional protection for
the boiler. It is recommended but not compul-
sory.
e Ø 80/80 separating device cannot be
used in this con guration.
e ue pipe (both
is will ensure
12
13
13
14