Immergas VICTRIX TERA 24 PLUS Instruction Booklet And Warning page 34

Wall-hung condensing boilers with sealed chamber type c and fan assisted or with open chamber type b and fan assisted which can be coupled to separate storage tank unit
Hide thumbs Also See for VICTRIX TERA 24 PLUS:
Table of Contents

Advertisement

Id
Parameter
Parameter
Max DHW
De nes the maximum heat output percentage of the boiler during the D.H.W.
P0
output
phase compared to the maximum heat output available
P1
Min CH output
De nes in percentage the minimum output in central heating mode
De nes the maximum heat output percentage of the boiler during the central
P2
Max CH output
heating mode compared to the maximum heat output available
P3
-
Not available for this model
0 intermittent: in winter "mode" the circulator is managed by the room
Pump function-
P4
ing
1 continuous: in "winter" mode the circulator is always powered and is
External probe
If the reading of the external probe is not correct it is possible to correct it
P5
correction
in order to compensate any environmental factors.
P6
-
Not available for this model
P7
-
Not available for this model
Id
Parameter
Parameter
Central heating
set point min-
t0
De nes the minimum ow temperature.
imum temper-
ature
Central heating
set point max-
t1
De nes the maximum ow temperature.
imum temper-
ature
t2
-
Not available for this model
In winter mode the boiler, at the end of a domestic hot water request, is
Domestic hot
ready to switch to central heating mode if there is an active request. Timing
t3
water priority
sets a time period in which the boiler waits before changing the operating
timing
mode, in order to quickly and comfortably satisfy an additional request for
domestic hot water.
Central heating
t4
ignitions timer
too o en in central heating mode
Central heating
In the heating stage, the boiler performs an ignition ramp in order to reach
t5
ramp timer
the maximum output set
CH ignition de-
t6
lay from TA and
particular systems (e.g. area systems with motorised thermostatic valves
CR request
etc.) it may be necessary to delay ignition
Establishes the display lighting mode.
0 : the display lights up during use and lowers a er 15 seconds of inactivity.
t7
Display lighting
1 : display lighting o .
2 : the display is always lit up.
Establishes what the indicator displays 19 (Fig. 35).
"Summer" mode:
0:
1:
t8
Display
"Winter" mode:
0:
1:
Flow o tempera-
Increases the ow o temperature at ignition only in the rst 60 seconds.
t9
ture increase
Description
e pump can function in two ways.
thermostat or by the remote control
therefore always in operation
Description
e boiler has electronic timing, which prevents the burner from igniting
e boiler is set to switch-on immediately a er a request. In the event of
In the case of anomaly the display ashes.
the indicator is always o
pump active displays the ow temperature,
pump o the indicator is o
always displays the value set on the CH selector
pump active displays the ow temperature,
pump o always displays the value set on the CH selector
A er the ame is detected, the temperature is increased by t9
34
Customised
Range
Default
value
0 - 100 %
100 %
0 - P2
0 %
G20 = 85
0 - 100 %
G31 = 82
-
-
0 - 1
0
-9 ÷ 9 K
0
-
-
-
-
Customised
Range
Default
value
20 ÷ 50 °C
25
(t0+5) ÷
85
85 °C
-
-
0 - 100
seconds
2
(step 10 sec)
0 - 600
seconds
18
(step 10 sec)
0 - 840
seconds
18
(step 10 sec)
0 - 600
seconds
0
(step 10 sec)
0 - 2
0
0 - 1
1
0 - 15
0