Using The Boiler - Immergas VICTRIX TERA 24 PLUS Instruction Booklet And Warning

Wall-hung condensing boilers with sealed chamber type c and fan assisted or with open chamber type b and fan assisted which can be coupled to separate storage tank unit
Hide thumbs Also See for VICTRIX TERA 24 PLUS:
Table of Contents

Advertisement

2.4 USING THE BOILER.

Before ignition make sure the heating system
is lled with water and that the manometer (8)
indicates a pressure of 1 ÷ 1.2 bar.
- Open the gas cock upstream from the boiler.
- Press the button "
" repeatedly to
cyclically switch from "stand-by" (
"summer" (
) and "winter" (
• Summer (
): in this mode the boiler func-
tions only to produce the DHW, the temper-
ature is set via the buttons "
relative temperature is shown on the display
via the indicator (19). Moreover, the tempera-
ture level that can be selected is shown on the
indicator (22).
• Winter (
): in this mode the boiler works
both for producing domestic hot water and
for central heating.
e DHW temperature is
always regulated via the buttons "
central heating temperature is regulated via the
buttons "
" and the relative temperature
is shown on the display via the indicator (19).
Moreover, the temperature level that can be
selected is shown on the indicator (15).
From this moment the boiler functions automat-
ically. With no demand for heat (central heating
or domestic hot water production) the boiler
goes to "standby" function, equivalent to the
boiler being powered without presence of ame.
Each time the burner ignites, the relative ame
present symbol is displayed (11) with relative
output scale.
• Operation with Comando Amico Remoto
remote control
V2
(CAR
V2
) (Optional). If the
V2
CAR
is connected, the (
appear on the display.
e boiler regulation pa-
rameters can be set via the CAR
V2
and the reset button (3) remains active on the
boiler control panel, along with the switch-o
button (1) ("o " mode only) and the display
where the functioning state is shown.
Caution: if the boiler is switched "o " the
V2
CAR
will display the connection error symbol
"ERR>CM", the CAR
V2
is however powered
constantly so as not to lose the stored programs.
• Solar operating mode (
).
is activated automatically id the boiler detects
a probe on the DHW inlet (optional) or if the
"Solar ignition delay" parameter is more than
0 seconds.
During a withdrawal, if the outlet water is hot
enough or if there is "Solar ignition delay" time,
the boiler does not switch on, the D.H.W. with-
drawal symbol (
along with the ashing solar function symbol
).
(
) to
When the water supplied by the solar system
is at a temperature lower than what is set, or
) mode.
if the "Solar ignition delay" time has elapsed,
the boiler switches on. At this point, the solar
function symbol remains permanently on.
• Operation with optional external probe
" and the
(
). In the case of a system with optional
external probe, the boiler ow temperature
for room central heating is managed by the
external probe depending on the external
temperature measured (Par. 1.10).
temperature can be modi ed by selecting the
functioning curve via the buttons "
on the CAR
V2
control panel, if connected to the
", the
boiler) selecting a value from "0 to 9".
With external probe present, the relative
symbol (12) will appear on the display. In the
central heating mode, if the temperature of the
water contained in the system is su cient to
heat the radiators, the boiler can only function
with the activation of the pump.
• "Stand-by" mode. Press button "
peatedly until the symbol (
now on the boiler remains inactive and the
antifreeze function, pump anti-block function
and 3-way and signalling of any anomalies is
guaranteed.
N.B.: in these conditions the boiler is still
powered.
) symbol will
• "O " mode. By holding the button "
down for 8 seconds, the display switches-o
control panel
and the boiler is o completely.
functions are not guaranteed in this mode.
N.B.: while not having functions active, in these
conditions the boiler must be considered still
live.
is state is displayed by a "dot" lit in the
centre of the display.
• Display functioning.
while the control panel is being used; a er
a set inactivity period, the brightness drops
is function
until only the active symbols are displayed.
lighting mode can be varied via parameter "t8"
in the P.C.B. programming menu.
) appears on the display
e ow
" (or
" re-
) appears. From
"
e safety
e display lights up
e
25