Internal Installation Using A Recessed Frame With Direct Air Intake - Immergas VICTRIX TERA 24 PLUS Instruction Booklet And Warning

Wall-hung condensing boilers with sealed chamber type c and fan assisted or with open chamber type b and fan assisted which can be coupled to separate storage tank unit
Hide thumbs Also See for VICTRIX TERA 24 PLUS:
Table of Contents

Advertisement

1.14 INTERNAL INSTALLATION USING
A RECESSED FRAME WITH DIRECT
AIR INTAKE
• Con guration type B, open chamber and fan
assisted.
Using a kit separator one can achieve direct air
intake (Fig. 16) and ue gas exhaust in a single
chimney or directly outside. In this con guration
the boiler is classi ed as type B
.
23
With this con guration:
- air intake takes place directly from the envi-
ronment in which the appliance is installed
(the recessed frame is ventilated), and only
functions in permanently ventilated rooms;
- the ue gas exhaust must be connected to its
own individual ue or channelled directly into
the external atmosphere.
The technical regulations in force must be
respected.
Separator kit installation: install the discharge
ange on the central hole of the boiler, posi-
tioning the relative gasket with the circular
projections downwards in contact with the
boiler ange, and tighten using the hex screws
with at tip contained in the kit. Remove the at
ange present in the lateral hole with respect to
the central one (according to needs) and replace
it with the intake ange, positioning its gasket
already present in the boiler and tighten using
the supplied self-threading screws. Fit the male
side (smooth) to the bends in the female side of
the anges.
e intake bend must face the rear side of the
boiler.
Fit the exhaust pipe with the male side (smooth)
to the female side of the bend up to the end stop,
making sure that the internal wall sealing plate
has been tted and connecting the required ue
according to personal requirements.
Max. length of exhaust duct.
e ue pipe (both
vertical or horizontal) can be extended to a max.
length of 30 linear metres.
14
15
16

Hide quick links:

Advertisement

Table of Contents
loading