VICTRIX 50 combustion parameters.
Gas nozzle diameter
Supply pressure
Flue flow rate at nominal heat output
Flue flow rate at minimum heat output
CO
at Q. Nom./Min.
2
CO at 0% of O
at Q. Nom./Min.
2
NO
at 0% of O
at Q. Nom./Min.
X
2
Flue temperature at nominal heat output
Flue temperature at minimum heat output

VICTRIX 50 variable heat output.

HEAT
HEAT
OUTPUT
OUTPUT
(kW)
(kcal/h)
50,0
43000
48,0
41280
46,0
39560
44,0
37840
42,0
36120
41,2
35398
38,0
32680
36,0
30960
34,0
29240
32,0
27520
30,0
25800
28,0
24080
26,0
22360
24,0
20640
22,0
18920
20,0
17200
18,0
15480
16,0
13760
14,0
12040
12,0
10320
10,0
8600
STV50 ed 09/08
mbar (mm H
NATURAL GAS (G20)
BURNER GAS
FAN SPEED (RPM)
FLOW RATE
(m
/h)
(n°)
3
5,37
5180
5,16
5000
4,95
4810
4,74
4620
4,53
4430
4,45
4350
4,11
4050
3,90
3860
3,69
3670
3,48
3470
3,26
3280
3,05
3080
2,84
2890
2,62
2690
2,41
2490
2,19
2290
1,97
2090
1,76
1890
1,54
1690
1,32
1490
1,10
1280
38
Technical Documentation
G20
mm
7,85
O)
20 (204)
2
kg/h
81
kg/h
17
%
9,32 / 9,25
ppm
130 / 5
ppm
69 / 28
°C
41
°C
47
BUTANE (G30)
BURNER GAS
FAN SPEED (RPM)
FLOW RATE
(kg/h)
(n°)
4,01
4600
3,85
4430
3,70
4260
3,54
4090
3,38
3910
3,32
3840
3,07
3570
2,91
3390
2,75
3220
2,59
3050
2,44
2880
2,28
2700
2,12
2530
1,96
2360
1,80
2190
1,63
2010
1,47
1840
1,31
1670
1,15
1500
0,99
1330
0,82
1150
G30
G31
5,70
5,70
29 (296)
37 (377)
72
81
15
17
12,30 / 11,70
10,60 / 10,10
425 / 10
120 / 7
342 / 85
119 / 43
46
42
51
47
PROPANE (G31)
BURNER GAS
FAN SPEED (RPM)
FLOW RATE
(kg/h)
(n°)
3,94
5200
3,79
5000
3,64
4790
3,48
4590
3,33
4380
3,26
4300
3,02
3980
2,86
3780
2,71
3580
2,55
3380
2,40
3180
2,24
2980
2,08
2790
1,92
2590
1,77
2400
1,61
2200
1,45
2010
1,29
1820
1,13
1630
0,97
1440
0,81
1250
VICTRIX 50 Rev. 002