TECHNICAL DATA.

4.1

VARIABLE HEAT OUTPUT.

N.B.: the pressures indicated in the tables represent the difference
in existing pressures between the gas valve outlet and the com-
bustion chamber. The adjustments should therefore,be carried
out using a differential manometer (small "U"-shaped column
or digital manometer) with the probes inserted in the pressure
test gas valve outlet and on the sealed chamber positive pressure
HEAT
INPUT
(kW)
25.5
12.8
7.6
4.2

COMBUSTION PARAMETERS.

Gas nozzle diameter
Supply pressure
Flue flow rate at nominal central heating output
Flue flow rate at min central heating output
CO
at Nom.
2
O
at Nom.
2
CO
at Min.
2
O
at Min.
2
CO with 0% O
at Nom./Min. Q.
2
NO
with 0% O
at Nom./Min. Q.
X
2
Flue temperature at nominal output
Flue temperature at minimum output
Combustion parameters: measuring conditions of useful efficiency
(flow temperature/return temperature= 80 / 60 °C), ambient tem-
perature reference = 15°C.
HEAT
OUTPUT
(kW)
RISC
23.5
+
SANIT
11.3
6.7
SANIT
test. The power data given in the table is obtained with 0.5m long
intake/exhaust pipe. Gas flow rates refer to heating power below a
temperature of 15°C and pressure of 1013 mbar. Burner pressure
values refer to use of gas at 15°C.
METHANE (G20)
GAS FLOW
GAS PRESSURE
RATE BURNER
(kg/h)
(kPa)
2.70
1.14
1.35
0.31
0.80
0.12
mm
mbar (mm H
kg/h
kg/h
ppm
mg/kWh
PROPANE (G31)
GAS FLOW
GAS PRESSURE
RATE BURNER
(%)
(kg/h)
(kPa)
100
1.04
3.62
19
0.52
0.94
0
0.31
0.37
G20
1.35
O)
20 (204)
2
53
55
6.90
%
8.50
3.20
%
15.20
79 / 75
215 / 151
°C
128
°C
108
(%)
100
18
0
G31
0.79
37 (377)
54
57
7.80
9.00
3.50
15.60
65 / 76
279 / 187
133
110
47