Epson PP-100II Technical Reference Manual page 49

Td bridge
Hide thumbs Also See for PP-100II:
Table of Contents

Advertisement

PLUG_IN_PARAMETER
Parameters to be specified in Read Back Plug-in are shown below.
To specify multiple parameters, separate each with " " (a single-byte space).
Content to be
specified
Read back type
Specifies whether to read files written in a disc as-is or
create a disc image file.
"-k" + " "(single-byte space) + number
1 is specified for the number :
Copy files.
2 is specified for the number :
Create a disc image file.
If a value other than the above is specified or if a value is
omitted, the same operation as when 1 is specified will
be performed.
Creating a folder for
Specifies whether to create a sub-folder for each disc to
each disc to be read
be read. This parameter is enabled only when "Copy files
("-k1") is specified for the read back type.
"-f" + " "(single-byte space) + number
1 is specified for the number :
Creates a sub-folder for each disc and saves read files
under that folder. All the files read will be saved in there.
2 is specified for the number :
Copies all the files into the folder specified as "save
destination folder".
If multiple files with the same name exist, only the most
recently updated file will be saved.
If a value other than the above is specified or if a value is
omitted, the same operation as when 1 is specified will
be performed.
Save destination
Specifies the folder to store files read from discs.
folder
"-r" + " "(single-byte space) + folder's full path
Chapter 4 Development Guide for a Cooperative Application
Description
Setting example
Copy files.
-k 1
Create a disc image.
-k 2
Create a folder for each disc.
-f 1
Do not create a folder for each disc.
-f 2
Save read files under the
"c:\readdata" folder.
-r "c:\readdata"
Necessary/
Arbitrary
Arbitrary
Arbitrary
4
Necessary
49