Advertisement

Batt Type
SEALED
Batt AH
200AH
Equalize Time
120 min
Boost Time
120 min
You should input the user password (see above) before setting the parameters.
In setting mode, all the parameters can be modified. And will immediately
effect when saved. The detail and value range of control parameter are shown
in the tables below:
Battery Charging Setting
Battery Type
Sealed (Default)
GEL
Flooded
User
Others
Parameter
Battery capacity
Temperature compensate
coefficient
Rated system voltage
Temp Coefficient
-3mV/℃/2V
Rated Volt
AUTO
Low Volt Disc
11.1V
Discharge Limit
10.6V
Default value
200Ah
-3mV/º C/2V
Auto
Over Volt. Disc.
16.0V
Charge Limit
15.0V
Under Volt Rect
12.2V
Under Volt Warn
12.0V
Note
Constant value
Constant value
Constant value
Defined by user
25
Over Volt. Rect
15.0V
Equalize Charge
14.6V
Boost Charge
14.4V
Float Charge
13.8V
Boost Rect Volt
13.2V
Low Volt Rect
12.6V
Range
1~9999Ah
-9~0 mV/º C/2V
12/24/36/48VDC Auto