www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 30”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing & Cap Side wall cap w/ gravity damper Soffit or crawl space...
ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. 4” prepare hood. Refer to page 11 for horizontal ducting conversion. wood board 2. Plum and mark center line on wall. ” line A. 5.
This range hood is equipped standard with a 10” round vertical duct option. To convert from 10” round vertical to 10” round horizontal ducting please following the instructions below. VERTICAL TO HORIZONTAL DUCTING CONVERSION 1. Disconnect blower plug. attaching blower plate to top of hood body. Remove blower and blower plate.
www.zephyronline.com 1 Blower On/Off/Speed Selection 2 Lights Dim/Bright/Off 1 Blower On/Off/Speed Selection Rotate dial to change speed levels, (1) for low speed, (2) for medium speed and (3) for high speed 2 Lights Dim/Bright/Off Rotate dial to change light settings, (1) for dim light and (2) for bright light...
SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless should never need replacing, they are required to be cleaned every 30 days or more often depending on cooking habits.
Page 16
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. diameter of the bulb or use a rubber/latex glove and turn counter clockwise. For Zephyr part numbers please turn to page 18 of the manual.
TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
www.zephyronline.com MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7836BS / AK7842BS CIRCUIT DIAGRAM B 34 B 34 MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7848BS / AK7854BS CIRCUIT DIAGRAM B 34 B 34...
www.zephyronline.com DESCRIPTION PART # Replacement Parts Optional Accessories To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.