Summary of Contents for Zephyr AK7000AS

  • Page 1 Tempest I AK7000AS AK7036AS AK7042AS Model number: Serial Number: Date of Purchase: Sales Dealer: MAY12.0701 © 2012 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifi cations ............... Mounting the Range Hood 9-10 ........Horizontal Conversion 11-12 ..........PBD-1100A Dual Blower 13-14 .......... ACCESSORY INSTALLATION Heat Lamp Kit ...............
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5: Operation

    WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. No for use over an outdoor grill.
  • Page 6: Hardware Package Contents

    MODELS: AK7000AS, AK7036AS, AK7042AS PARTS SUPPLIED 1 - Hood 2 - Baffl e fi lters (3 - AK7036AS and AK7042AS) 2 - Halogen light bulbs (pre-installed) 1 - Single internal blower and blower plate w/damper (pre-installed) 1 - Rectangular starting collar (for single blower horizontal ducting) 1 - 6”...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
  • Page 8 www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fi...
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options Ductless Recirculating...
  • Page 10 www.zephyronline.com ” (30”) ” (36”) ” (42”) 13/16 ” 3/16 3” 12” elec ” (30”) 15/16” (36”) 15/16” (42”) 15/16” side ” (30”) ” (36”) ø 9 15/16” ” (42”) 13/16 3” 15/16” (30”) 15/16” (36”) 15/16” (42”) 15/16” back with 10”...
  • Page 11 ELECTRICAL WARNING All Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 www.zephyronline.com For dual blower installation instructions please refer to page 13. If recirculating range hood refer to the manual included with ZRC-07xx recirculating kit or on our 5. Duct opening website prior to installing hood. Recirculating kit cutout compatible with 600cfm single internal blower only. For Mounting Under a Kitchen Cabinet duct/silver 1.
  • Page 13 This range hood is equipped standard with a 6” round vertical duct option. To convert from 6” round vertical to 3-1/4” x 10” horizontal ducting please following the instructions below. NOTE: Horizontal ducting is only available for the single internal blower. VERTICAL TO HORIZONTAL DUCTING CONVERSION 1.
  • Page 14 www.zephyronline.com 6. On the back of the hood, remove the (6) screws 7. Place round to rectangular transition adapter holding the rectangular cap. inside hood and line it up with the rectangular opening. Attach with (4) M4x8 screws from the outside.
  • Page 15 DUAL BLOWER INSTALLATION* *IMPORTANT: Dual blower and heat lamps may only be used together in 42” models. 30” and 36” models will only accommodate one or the other, not both at the same time. 1. Disconnect single blower wire. 2. Remove support screw from top of hood near the back.
  • Page 16 www.zephyronline.com 8. Place 10” round adapter (included with PBD- 7. Secure dual blower plate to hood by following 1100A) on top of hood and secure with (4) removal instructions in reverse. Attach blower M4x8 screws. Connect 10” duct work. wire to hood. The 10”...
  • Page 17 HEAT LAMP KIT INSTALLATION* *IMPORTANT: Dual blower and heat lamps may only be used together in 42” models. 30” and 36” models will only accommodate one or the other, not both at the same time. 2. Replace bottom panel with heat lamp bottom 1.
  • Page 18 www.zephyronline.com Lights On/Dim/Off Display (Speed level, Delay Off Indicator) 5 Min Delay Off Blower On/Off Adjust 3 Speed Levels Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower turns on at the same speed it was switched off at.
  • Page 19 Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to be replaced after every 120 hours of use.
  • Page 20 www.zephyronline.com Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
  • Page 21: Surface Maintenance

    2. Pivot front of fi lter downward. 3. Remove fi lter by pulling away from hood. Replacing Baffle Filters Hood Model: Part No. Qty. to Order. AK7000AS 50210004 AK7036AS 50210004 AK7042AS 50210004 Recirculating Kit (includes charcoal fi lters and air diverter) Hood Model: Part No.
  • Page 22: Replacing Light Bulbs

    If bulbs are diffi cult to turn due to prolonged use, fi rmly attach the provided glass suction cup or use a rubber/ latex glove and turn counter clockwise. Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. For Zephyr part numbers please turn to page 22 of the manual.
  • Page 23 TROUBLESHOOTING PROCEDURES FOR TEMPEST I Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 24 www.zephyronline.com DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baffl e Filter (each) 50210007 Optional Accessories *Dual Internal Blower (w/ 1 blower) PBD-1100A* Heat Lamp Kit (30”) * AK0700AS Heat Lamp Kit (36”) * AK0706AS Heat Lamp Kit (42”) * AK0702AS Back Splash (30”) AK0710...
  • Page 25 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Ten Year Limited Warranty for Parts: For ten years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.