Download Print this page

Step 2 - Keypad Operation Overview - Eaton PowerXL DG1 Series VFD Quick Start Manual

Hide thumbs Also See for PowerXL DG1 Series VFD:

Advertisement

Step 2 — Keypad overview
The keypad is the interface between the drive and the user.
It features an LCD display, 3 LED lights and 11 buttons. With
the control keypad, it is possible to control the speed of a
motor, to supervise the state of the equipment and to set
the frequency converter's parameters. See Figure 3.
Keypad buttons
Buttons description
Table 2. Keypad Buttons
Icon
Button
Soft key 1,
Soft key 2
Back/Reset
Local/Remote
Up
Down
POWERXL DG1 SERIES ADJUSTABLE FREQUENCY DRIVES MN040012EN—December 2017 www.eaton.com
Description
Soft key 1, soft key 2:
The functions of these two buttons shall be the following:
Forward/Reverse, this shall change motor's run direction.
Menu, this shall return to main menu
Details, this shall display the details of the fault
Bypass, this shall make drive go into bypass
Jog, this shall activate jog
Favorite, this shall add this parameter to the Favorite menu
Delete, this shall delete this parameter from the Favorite menu
Back/Reset:
This button has three integrated functions. The button operates as backward button
during normal mode. In edit mode, it is used as cancel operate. It is also used to reset faults when faults occur.
Backs up one step
Cancels Modify in edit mode
Resets the active faults (all the active faults shall be reset by pressing this button more than 2s in any page)
Hold Stop and Back Reset for 5 seconds to return drive to factory default
At Main Menu page by hitting Back/Reset takes to Default Page.
Local/Remote:
Switches between LOCAL and REMOTE control for start and speed reference. The control
locations corresponding to local and remote shall be selected within an application.
Up and down arrows:
Move either up or down a menu list to select the desired menu item.
Editing a parameter bit by bit, while the active digit is scrolled.
Increase/decrease the reference value of the selected parameter.
In parameter comparison mode, scroll through the parameters of which current value is different from comparison
parameter value.
In parameter page when in read mode, move to the previous or next brother parameter of this parameter.
Step 2 — Keypad overview
3

Hide quick links: