1..
Load and Motor
#
Parameter
Description
100
Configuration
101
Torque Characteristics
102
Motor Power
103
Motor Voltage
104
Motor Frequency
105
Motor Current
106
Rated Motor Speed
107
Automatic Motor Adaptation, AMA
108
Start Voltage of Parallel Motors
109
Resonance Dampening
110
High Breakaway Torque
111
Start Delay
112
Motor Preheater
113
Motor Preheater DC Current
114
DC Braking Current
115
DC Braking Time
116
DC Brake Cut-in Frequency
117
Motor Thermal Protection
118
Motor Power Factor (Cos
2..
References and Limits
#
Parameter
Description
200
Output Frequency Range
201
Output Frequency Low Limit
202
Output Frequency High Limit
203
Reference Handling
204
Minimum Reference
205
Maximum Reference
206
Ramp-up Time
207
Ramp-down Time
208
Automatic Ramp-up/down
209
Jog Frequency
210
Reference Type
211
Preset Reference 1
212
Preset Reference 2
213
Preset Reference 3
214
Preset Reference 4
215
Current Limit
216
Frequency Bypass Bandwidth
217
Frequency Bypass 1
218
Frequency Bypass 2
219
Frequency Bypass 3
220
Frequency Bypass 4
221
Warning: Low Current
222
Warning: High Current, I
223
Warning: Low Frequency
224
Warning: High Frequency
225
Warning: Low Reference
226
Warning: High Reference
227
Warning: Low Feedback
228
Warning: High Feedback
104
Factory Setting
OPEN LOOP
AEO FUNCTION
Depends on the unit
Depends on the unit
60 Hz
Depends on the unit
Depends on
par. 102 Motor power
NO AMA
Depends on par. 103
100%
OFF
000.0 s
DISABLE
50%
50%
10.0 s
OFF
ETR TRIP 1
Æ
0.75
)
Factory Setting
0 - 120 Hz
Fans=6 Hz, Pumps=18 Hz
60 Hz
LINKED TO HAND/AUTO
Fans=6 Hz, Pumps=18 Hz
000060.000 Hz
Fans=60 sec., Pumps=10 sec. 1 - 3600 sec.
Fans=60 sec., Pumps=10 sec. 1 - 3600 sec.
ENABLE
10.0 Hz
EXTERNAL PRESET
0.00%
0.00 %
0.00 %
0.00 %
Depends on the unit
DISABLED
120.0 Hz
120.0 Hz
120.0 Hz
120.0 Hz
0.0 A
I [A]
0.0 Hz
120.0 Hz
-999,999.999 Hz
999,999.999 Hz
-999,999.999 Hz
999,999.999 Hz
Range
Changes
During Operation
No
No
0.25 - 500 kW
No
200 - 575 V
No
24 - 1000 Hz
No
0.01 - I
No
100 - 60000 rpm
No
No
0.0 - par. 103
Yes
0 - 500 %
Yes
0.0 - 0.5 sec.
Yes
0.0 - 120.0 sec.
Yes
Yes
0 - 100 %
Yes
0 - 100 %
Yes
0.0 - 60.0 sec.
Yes
0.0 - par. 202
Yes
Yes
0.50 - 0.99
No
Range
Changes
during operation
0 - 1000 Hz
No
0.0 - par. 202
Yes
par. 201 - par. 200
Yes
Yes
0.000-Ref
Yes
MAX
Ref
-999.999,999
Yes
MIN
Yes
Yes
Yes
par. 201 - par. 202
Yes
Yes
-100.00 - 100.00 %
Yes
-100.00 - 100.00 %
Yes
-100.00 - 100.00 %
Yes
-100,00 - 100,00 %
Yes
0 - I [A]
Yes
0 - 120 Hz
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 222
Yes
Par. 221 - I [A]
Yes
0.0 - par. 224
Yes
Par. 223 - par. 200/202 Yes
-999,999.999 - par. 226 Yes
Par. 225 - 999,999.999 Yes
-999,999.999 - par. 228 Yes
Par. 227 - 999,999.999 Yes
4-Setup
Conversion
Data
Index
Type
Yes
0
5
Yes
0
5
Yes
-2
6
Yes
0
6
Yes
0
6
Yes
-2
7
Yes
0
6
No
0
5
Yes
-1
6
Yes
0
6
Yes
-1
5
Yes
-1
6
Yes
0
5
Yes
0
6
Yes
0
6
Yes
-1
6
Yes
-1
6
Yes
0
5
Yes
-2
3
4-Setup
Conversion
Data
Index
Type
Yes
0
5
Yes
-1
6
Yes
-1
6
Yes
0
5
Yes
-3
4
Yes
-3
4
Yes
0
7
Yes
0
7
Yes
0
5
Yes
-1
6
Yes
0
5
Yes
-2
3
Yes
-2
3
Yes
-2
3
Yes
-2
3
Yes
-1
6
Yes
0
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-3
4
Yes
-3
4
Yes
-3
4
Yes
-3
4

Hide quick links: