Specifications

8.1.3 Mains Supply 3x525-600 V AC

Type Designation
Typical Shaft Output [kW]
IP20/Chassis
IP21/NEMA 1
IP55/Type 12
IP66/NEMA 4X
Output current
Continuous (3x525-550 V) [A]
Intermittent (3x525-550 V) [A]
Continuous (3x525-600 V) [A]
Intermittent (3x525-600 V) [A]
Continuous kVA (525 V AC) [kVA]
Continuous kVA (575 V AC) [kVA]
Max. input current
Continuous (3x525-600 V) [A]
Intermittent (3x525-600 V) [A]
Additional specifications
Estimated power loss
at rated max. load [W]
4)
IP20 max. cable cross-section
5)
(mains, motor, brake and load
2
sharing) [mm
/(AWG)]
IP55, IP 66 max. cable cross-section
5)
(mains, motor, brake and load
sharing) [mm
2
/(AWG)]
Max. cable cross-section with
disconnect
Mains disconnect switch included:
Efficiency
3)
Table 8.5 Mains Supply 3x525-600 V AC - Normal overload 110% for 1 minute, P1K1-P7K5
®
VLT
HVAC Drive Operating Instructions
P1K1
P1K5
P2K2
1.1
1.5
2.2
A3
A3
A3
A3
A3
A3
A5
A5
A5
A5
A5
A5
2.6
2.9
4.1
2.9
3.2
4.5
2.4
2.7
3.9
2.6
3.0
4.3
2.5
2.8
3.9
2.4
2.7
3.9
2.4
2.7
4.1
2.7
3.0
4.5
50
65
92
0.97
0.97
0.97
MG11AJ02 - Rev. 2013-07-31
P3K0
P3K7
P4K0
3.0
3.7
4.0
A3
A2
A3
A3
A2
A3
A5
A5
A5
A5
A5
A5
5.2
-
6.4
5.7
-
7.0
4.9
-
6.1
5.4
-
6.7
5.0
-
6.1
4.9
-
6.1
5.2
-
5.8
5.7
-
6.4
122
-
145
4, 4, 4 (12, 12, 12)
(min. 0.2 (24))
4, 4, 4 (12, 12, 12)
(min. 0.2 (24))
6, 4, 4 (12, 12, 12)
4/12
0.97
-
0.97
P5K5
P7K5
5.5
7.5
A3
A3
A3
A3
A5
A5
A5
A5
9.5
11.5
10.5
12.7
9.0
11.0
9.9
12.1
9.0
11.0
9.0
11.0
8.6
10.4
9.5
11.5
8
195
261
0.97
0.97
47