Mains Supply 3X380-480 V Ac - Danfoss VLT FC 102 Operating Instructions Manual

1.1-90 kw hvac drive
Hide thumbs Also See for VLT FC 102:
Table of Contents

Advertisement

Specifications

8.1.2 Mains Supply 3x380-480 V AC

Type Designation
Typical Shaft Output [kW]
Typical Shaft Output [HP] at 460 V
6)
IP20/Chassis
IP55/Type 12
IP66/NEMA 4X
Output current
Continuous (3x380-440 V) [A]
Intermittent (3x380-440 V) [A]
Continuous (3x441-480 V) [A]
Intermittent (3x441-480 V) [A]
Continuous kVA (400 V AC) [kVA]
Continuous kVA (460 V AC) [kVA]
Max. input current
Continuous (3x380-440 V) [A]
Intermittent (3x380-440 V) [A]
Continuous (3x441-480 V) [A]
Intermittent (3x441-480 V) [A]
Additional specifications
Estimated power loss
4)
at rated max. load [W]
IP20, IP21 max. cable cross-section
(mains, motor, brake and load
sharing) [mm
2
/(AWG)]
2)
IP55, IP66 max. cable cross-section
(mains, motor, brake and load
2
2)
sharing) [mm
/(AWG)]
Max. cable cross-section with
disconnect
3)
Efficiency
Table 8.3 Mains Supply 3x380-480 V AC - Normal overload 110% for 1 minute, P1K1-P7K5
®
VLT
HVAC Drive Operating Instructions
P1K1
P1K5
P2K2
1.1
1.5
2.2
1.5
2.0
2.9
A2
A2
A2
A4/A5
A4/A5
A4/A5
A4/A5
A4/A5
A4/A5
3
4.1
5.6
3.3
4.5
6.2
2.7
3.4
4.8
3.0
3.7
5.3
2.1
2.8
3.9
2.4
2.7
3.8
2.7
3.7
5.0
3.0
4.1
5.5
2.7
3.1
4.3
3.0
3.4
4.7
58
62
88
0.96
0.97
0.97
MG11AJ02 - Rev. 2013-07-31
P3K0
P4K0
3.0
4.0
4.0
5.0
A2
A2
A4/A5
A4/A5
A4/A5
A4/A5
7.2
10
7.9
11
6.3
8.2
6.9
9.0
5.0
6.9
5.0
6.5
6.5
9.0
7.2
9.9
5.7
7.4
6.3
8.1
116
124
4, 4, 4 (12, 12, 12)
(min. 0.2 (24))
4, 4, 4 (12, 12, 12)
6, 4, 4 (10, 12, 12)
0.97
0.97
P5K5
P7K5
5.5
7.5
7.5
10
A3
A3
A5
A5
A5
A5
13
16
14.3
17.6
11
14.5
12.1
15.4
9.0
11.0
8.8
11.6
11.7
14.4
12.9
15.8
9.9
13.0
10.9
14.3
8
187
255
0.97
0.97
45
8

Advertisement

Table of Contents
loading

Table of Contents