5.8 PPV8 (Automatic Filter Shaking
After Sweeping)
(B 1100 & B1100 PB 1230)
1. Select desired setting by "L" and "N" buttons
2. The corresponding bar starts blinking
3. Use "M" button to move the bar up and down
Up
= ON = after a minimum of 2 minutes of sweeping, shaking is automatically
switched on upon end of sweeping
Down = OFF = shaking is not automatically switched on upon end of sweeping
4. Save setting by pressing the green button ("O" button) as long as the dot appears
at the bottom right of the display
Foil 47