3.2 Check And Set
Options
1. Setting each option in the machine is required at the Dip switch B (see p. 22)
on the control electronics.
2. The Dip switches are assigned as follows:
Cleaning agent dosage (B1100 &B1100PB 1230) (set = "ON")
1:
2:
SWA (B1100 only)
3:
Side brush (B1100 & B1050PB)
4:
Tool (B1100 suction only)
Tool (B1100 PB1230 & B1050PB / CB
and B1050 PB 1230 Spraying and suction)
5:
Pre-sweeper (B1100 & B1050CB*
and B1100PB1230)
6:
Cylindrical brush deck (B1050 only)
7 - 8: not assigned, i.e. "OFF"
* - for the B1050CB the side broom is activated.
3. An option is set if the Dip switch is set to ON.
(set = "ON")
(set = "ON")
(set to "OFF")
(set = "ON")
(set = "ON")
(set = "ON")
Foil 24