Cleaning the extractor
Careful maintenance ensures the correct operation and optimal performance.
The hood must be disconnected from the electrical network, both by unplugging the appliance
from the socket and activating the magnetic circuit breaker (safety cut-out), before removing
the metal grease filters. After cleaning operations, replace the metal grease filters as outlined
in the installation instructions.
MAINTENANCE
External surfaces and
accessories
Active charcoal filter
with extractable
unit open
Active charcoal filter
12
CAUTION
HOW TO PROCEED?
Do not use metallic scrubbers,
abrasive products, or hard brushes.
After 30 hours of operation, the
downdraft will signal the grease filter
saturation.
The saturation is signaled by the
blinking of the 4 central leds.
To reset, hold down the timer button
for at least 3 seconds, while the
carriage is open.
In the recirculation mode, the
active charcoal filter must be
replaced periodically.
To remove the charcoal filter first of all
it is necessary to remove the grease
filter and then pull the plastic key of
the panel itself, in order to disengage
it from its seating.
Follow these steps in reverse order to
insert the active charcoal filter.
Replace the used charcoal filter on
an average of every six months.
ACCESSORY PRODUCTS TO
USE
To clean the external surfaces of the
cookerhood and the light housing
screen use only commercially avail-
able household detergents diluted
in water. Then rinse with clean water
and dry with a soft cloth.
The grease filters can be washed by
hand or in the dishwasher. These fil-
ters need to be cleaned on a regular
basis, because otherwise they may
represent a fire risk.
Refit the grease filters and front
panel, making sure that the panis
properly fitted at the sides so that it
it does not cause the downdraft to
stop operating.