C L E A N I N G T H E E X T R A C T O R

Cleaning the extractor

Careful maintenance helps to ensure the correct operation and good performance over time.
C A U T I O N
Careful maintenance helps to ensure the correct operation and good performance over time.
The hood must be disconnected from the electrical network, both by unplugging the appliance
from the socket and activating the magnetic circuit breaker (safety cut-out), before removing the
CAUTION
metal grease filters. After cleaning, replace the metal grease filters as outlined in the installation
The hood must be disconnected from the electrical network, both by unplugging the appliance from
the socket and activating the magnetic circuit breaker (safety cut-out), before removing the metal
instructions.
grease filters. After cleaning, replace the metal grease filters as outlined in the installation
instructions.
M A I N T E N A N C E
H O W TO P R O C E E D ?
MAINTENANCE
HOW TO PROCEED?
External surfaces and
Do not use metallic scrubbers,
accessories
abrasive products, or hard brushes.
Do not use metallic scrubbers,
abrasive products or hard brushes.
External surfaces and
accessories
Grease filter with
After 30 hours of operation, the
After 30 hours of operation,
extractable unit open
downdraft will signal the grease filter
the downdraft will signal the grease
saturation.
filter saturation.
The saturation is signalled by the
The saturation is signaled by the
Grease filter with
blinking of the 4 central LED's.
blinking of the 4 central leds.To
extractable unit open
To reset, hold down the timer button
reset, hold down the timer button
for at least 3 seconds, while the
for at least 3 seconds, while the
carriage is open.
carriage is open.
Active charcoal filter
In the recirculation mode, the active
charcoal filter must be replaced
periodically.
In the recirculation mode, the
active charcoal filter must be
To remove the charcoal filter first
replaced periodically. To remove the
remove the grease filter and then pull
charcoal filter first of all it is
the plastic key of the panel itself, in
necessary to remove the grease
order to disengage it from its seating.
filter and then pull the plastic key
Follow these steps in reverse order to
Active charcoal filter
of the panel itself, in order to
insert the active charcoal filter.
disengage it from its seating.
Replace the used charcoal filter on an
Follow these steps in reverse order to
average of every six months.
insert the active charcoal filter.
Replace the used charcoal filter on
an average of every six months.
16
Instruction manual DD606BK
Please keep this instruction manual for future reference
A C C E S S O RY P R O D U C T S TO U S E
ADDITIONAL PRODUCTS TO
To clean the external surfaces of the cooker hood
USE
and the light housing screen use only commercially
To clean the external surfaces of the
avail-able household detergents diluted in water.
cooker hood and the light housing
Then rinse with clean water and dry with a soft
screen use only commercially avail-
cloth.
able household detergents diluted
in water. Then rinse with clean
water and dry with a soft cloth.
The grease filters can be washed by hand or in
The grease filters can be washed by
the dishwasher. These filters need to be cleaned
hand or in the dishwasher. These
on a regular basis, because otherwise they may
filters need to be cleaned on a
represent a fire risk.
regular basis, because otherwise
Refit the grease filters and front panel, making
they may represent a fire risk.
sure that the panel is properly fitted at the sides,
Refit the grease filters and
otherwise it may cause the downdraft to stop
front panel, making sure that the
operating.
panel is properly fitted at the sides,
otherwise it may cause the
downdraft to stop operating.
13
T R O U B L E S H O O T I N G
P R O B L E M
S O L U T I O N
The downdraft does not work
Check that:
» There is not a power outage.
» A specific speed has actually been selected.
» The red reset key, found over the electrical system box, is pushed.
» Make sure that the wires of the 9 pole connection are inserted
properly in the connector itself (during the connection phase, an
excessive pressure could bend the contacts).
The downdraft has low performance
Check that:
» The motor speed selected is sufficient for the quantity of fumes and
vapours present in the room.
» The kitchen is ventilated well enough to allow air for intake.
» The charcoal filter is not worn out. (Filtering version cooker hood).
» The air outlet channel is free and compliant with paragraph no.2.
» The non-return valves of the suctioning unit are free to rotate.
The downdraft stops in the middle of
Check that:
operation.
» There is not a power outage.
» The omnipolar device has not tripped.