Specifications; Temperature Compensation - Siemens Milltronics Pointek ULS200 Quick Start Manual

Ultrasonic switch
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Specifications

AC Version
Power
100 to 230 V AC, + 15%, 50/60 Hz, 12 VA
(5W) max.
Fuse
Slow-Blow, 0.25 A, 250 V AC
Output
repeatability: 0.25% of full range
resolution: 3 mm (0.1")
2
relay
:
2 Form C (SPDT) contacts,
rated max. 5A @ 250 V AC
/ 30 V DC non-inductive;
min. 10 mA @ 5 V DC
1.
Power
See
on page 8, for minimum supply voltage required with DC version.
2.
Interface
See
on page 7, for operation up to 48 V DC.
Environmental
• location:
• altitude:
• ambient temperature:
• relative humidity:
• installation category:
• pollution degree:
Process Pressure
• 0.5 bar (7.25 psi) max.
Switching Range
• liquids:
• solids:
Memory
• non-volatile EEPROM
Programming
• 2 keys

Temperature Compensation

• built-in to compensate over the operating range
Display
• LCD
• three 9 mm (0.35") digits for reading of distance between sensor face and material,
multi-segment graphic for operation status
A5E32268616
DC Version
Power
18 to 30 V DC, 3 W
Output
indoor/outdoor
2000 m max
- 40 to 60 °C (- 40 to 140 °F)
* - 20 °C (-5 °F) if metal mounting
suitable for outdoor (Type 6/NEMA 6/IP67 enclosure)
II
4
0.25 to 5 m (0.8 to16.4 ft)
0.25 to 3 m (0.8 to 9.8 ft)
Pointek ULS200 – QUICK START MANUAL
1
repeatability: 0.25 % of full range
resolution: 3 mm (0.1")
2
relay
:
2 Form C (SPDT)
contacts, rated max. 5 A
@ 30 V DC non-inductive;
min. 10 mA @ 5 V DC
OR
transistor: 2 transistor
switches, rated 
100 mA maximum at
48 V DC
Page EN-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents