Download Print this page

YASKAWA V1000 Installation Manual page 10

Compact vector control drive
Hide thumbs Also See for V1000:

Advertisement

3 Conditions of Acceptability
Figure 2
Output Voltage V
10.0
Figure 3 Output of Heatsink Plate Temperature by Analog Output
Note: 1. Accuracy of the temperature reading may vary ±5 ºC between 50 and 100 ºC.
2. The heatsink temperature is affected by the ambient temperature. Never exceed the allowable maximum
heatsink plate temperature.
Drive Overheat Alarm (oH)
Use parameter L8-02 to cause the drive output an alarm when the heatsink plate exceeds the
specified temperature.
L8-03 determines the action taken by the drive when an oH alarm is triggered. Refer to the
V1000 Technical Manual for more details.
Installation to Metallic Surface
The mating surface shall have the following properties:
• Surface flatness shall not exceed 0.2 mm across the entire mating surface.
• Surface roughness shall not exceed 25 S.
Note: A surface roughness of 25 S means "Ra" (average roughness) is not greater than 6.3 a and "Ry"
(maximum peak) is not greater than 25 μm.
Thermal Compound
Apply a thermal compound between the heatsink plate and the mating surface. The thermal
compound assists in drive heat dissipation.
Yaskawa recommends the thermal compounds in
10
9.0
5.0
0
YASKAWA ELECTRIC TOBP C710606 21D YASKAWA AC Drive - V1000 Finless Installation Guide