Allied Telesis AT-FH708SW Installation Manual
Allied Telesis AT-FH708SW Installation Manual

Allied Telesis AT-FH708SW Installation Manual

Dual-speed hubs

Advertisement

AT-FH708SW
AT-FH712SW
AT-FH716SW
AT-FH724SW
AT-FH716
Dual-speed Hubs

Installation Guide

PN 613-10710-00 Rev. G

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AT-FH708SW

  • Page 1: Installation Guide

    AT-FH708SW AT-FH712SW AT-FH716SW AT-FH724SW AT-FH716 Dual-speed Hubs Installation Guide PN 613-10710-00 Rev. G...
  • Page 2 Copyright  1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
  • Page 3: Statements

    Statements AT-FH708SW, AT-FH712SW, AT-FH716SW, AT-FH724SW or AT-FH716 in a Stacked Configuration FCC Warning RADIATED ENERGY U.S. Federal Communications Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4: Ce Mark Warning

    CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It confirms to the following specifications: EMC: EN55022 (1988)/CISPR-22(1985) Class A IEC1000-4-2(1995)
  • Page 5: At-Fh708Sw, At-Fh712Sw, At-Fh716Sw, At-Fh724Sw, At-Fh716 In A Standalone Operation Only

    Statements AT-FH708SW, AT-FH712SW, AT-FH716SW, AT-FH724SW, AT-FH716 in a Standalone Operation Only FCC Warning U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International, Corp. Manufacture Address: 960 Stewart Drive, Suite B Sunnyvale, CA 94086 USA Manufacture Telephone: 408-730-0950...
  • Page 6: Ce Mark Warning

    This product complies with the requirements of the Low Voltage Directive 73/23/ EEC and the EMC Directive 89/336/EEC. Warning Do not plug a phone jack connector in the RJ45 port. This may damage the device. AT-FH708SW, AT-FH716SW and AT-FH716 in a Stacked or Standalone Operation Safety Compliance UnderWriters Laboratories, Inc. (USA)
  • Page 7: At-Fh712Sw And At-Fh724Sw In A Stacked Or Standalone Operation

    Statements AT-FH712SW and AT-FH724SW in a Stacked or Standalone Operation Safety Compliance CSA/NRTL Important! Before making connections, make sure you have the correct cord set. Wichtige Sicherheitshinweise Bitte lesen Sie sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3.
  • Page 8 AT-FH700 Series Hubs Installation Guide 14. Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden. 15. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen: Netzkabel oder Netzstecker sind beschädigt.
  • Page 9: Table Of Contents

    AT-FH716 in a Standalone Operation Only ............iv FCC Warning....................iv CE Mark Warning .................... v AT-FH708SW, AT-FH716SW and AT-FH716 in a Stacked or Standalone Operation................... v AT-FH712SW and AT-FH724SW in a Stacked or Standalone Operation ..vi Safety Compliance CSA/NRTL............... vi Chapter 1 Product Description ....................
  • Page 10 Chapter 2 Installatio ......................9 Verifying Package Contents..................9 Site Requirements ....................10 Standalone Desktop Installation ................10 Rackmounting the Hubs..................11 Stacking the Hubs ....................12 Connecting Network Devices................13 Connecting Ethernet or Fast Ethernet Workstations ........13 Using An External Switch (AT-FH716) ............14 Using the Integrated Switch Module.............
  • Page 11: Product Description

    12, 16 and 24 dual-speed ports (10/100 Mbps). The hubs contain two internal repeater buses: one for 10 Mbps traffic and another for 100 Mbps traffic. The AT-FH708SW, AT-FH712SW, AT-FH716SW and AT-FH724SW hubs include an integrated two-port switch module that connects the 10 Mbps and 100 Mbps repeater buses.
  • Page 12 Table 1 summarizes the features of each hub model: Table 1 AT-FH700 Series Hub Models and Descripti o n Model Description AT-FH708SW Eight 10/100 Mbps twisted-pair ports One MDI/MDI-X switch associated with Port 8 Integrated switch module LED indicators for Power, Collision, Activity, Partition, and Link 10/100...
  • Page 13: Key Features

    ! Stacked configuration of up to six hubs with the use of a cascade cable, or standalone configuration ! Integrated switch module in the AT-FH708SW, AT-FH712SW, AT-FH716SW and AT-FH724SW models to allow transmissions between 10 Mbps and 100 Mbps devices connected to the hub stack...
  • Page 14: Front Panels

    To Hub COLLISION PARTITION 10M 100M POWER ACTIVITY LINK 10 X 11 X Figure 1 AT-FH708SW and AT-FH712SW Front Panels Port LEDs PARTITION 10BASE-T / 100BASE-TX 16 PORT DUAL SPEED HUB LINK To PC YELLOW 10Mbps GREEN 100Mbps To Hub...
  • Page 15: Front Panel Leds

    AT-FH700 Series Hubs Installation Guide Front Panel LEDs The AT-FH700 Series hubs’ front panel LEDs provide status in three areas: ! System-wide status ! Segment status ! Per-port status YELLOW 10Mbps GREEN 100Mbps PARTITION LINK Figure 5 A Close Up of the Port LEDs for the 8-Port Model LINK 1 2 3 4 5 6 7 8 9 10 11 12 100M...
  • Page 16: Front Panel Connectors

    Product Description For detailed explanations on the hubs’ front panel LEDs, see Tabl e2. Table 2 LED Indicators Description System Status Indicator: Power Steady green indicates the hub is receiving power. Segment Status Indicators (one each for the 10 Mbps and 100 Mbps segments): Collision Flashing amber indicates a collision has occurred in the 10 Mbps or 100 Mbps domain.
  • Page 17: Rear Panel

    AT-FH700 Series Hubs Installation Guide Rear Panel The rear panel shown in Figure 7 is common to all models. 100-240VAC 50-60Hz, 0.5A Figure 7 AT-FH700 Series Rear Panel Power Supply and Fan Power connection to the AT-FH700 Series hubs are done through the power receptacle in the rear panel.
  • Page 19: Installatio

    Chapter 2 Installation Verifying Package Contents Make sure that the package includes the following items: ! One AT-FH700 Series hub ! One AC power cord ! Two rackmount brackets and eight screws ! Four self-adhesive rubber feet ! One stacking cable ! Warranty card ! This installation guide If any of the above items is damaged or missing, contact your representative...
  • Page 20: Site Requirements

    Installation Site Requirements Make sure you observe the following site requirements: ! Choose a location that is less than 100 m (328 ft) away from servers, workstations, or switches. Caution Category 5 UTP/STP cables are environment-sensitive. Make sure the cable route is not too close to electrical noise sources such as power lines or fluorescent lights.
  • Page 21: Rackmounting The Hubs

    AT-FH700 Series Hubs Installation Guide Rackmounting the Hubs You will need a Phillips screwdriver for this installation. Disconnect all data cables and then the power cord, if attached. 2. Attach the brackets to the side of the hub with the screws provided. See Figure 8.
  • Page 22: Stacking The Hubs

    Installation Stacking the Hubs A stacking feature in each AT-FH700 Series hub’s rear panel gives you the advantage of stacking up to six AT-FH700 Series hubs and still have all front panel ports available for station connections. Stacking six 16-port hubs provides you a maximum of 96 connections belonging to the same collision domain.
  • Page 23: Connecting Network Devices

    This section shows you how to connect: ! Ethernet and Fast Ethernet workstations ! An external Fast Ethernet switch ! A hub with the integrated switch module (either the AT-FH708SW, AT-FH712SW, AT-FH716SW or AT-FH724SW) ! Other network devices via cascading This section also includes important information on cable length restrictions when cascading hubs.
  • Page 24: Using An External Switch (At-Fh716)

    Installation Using An External Switch (AT-FH716) If you require communication between devices of different transmission speeds across different domains, you may install an external 10/100 Mbps Fast Ethernet switch to the AT-FH716 hub (Figu re12). AT-8124 External Switch STATUS RS-232 PORT ACTIVITY TERMINAL PORT 10BASE-T / 100BASE-...
  • Page 25: Using The Integrated Switch Module

    AT-FH700 Series Hubs Installation Guide Using the Integrated Switch Module Using a hub with the integrated switch module (models AT-FH708SW, AT-FH712SW, AT-FH716SW or AT-FH724SW) is the easiest and most cost- effective solution to enable communication between devices of dissimilar speeds.
  • Page 26: Connecting Devices To The Mdi/Mdi-X Ports

    Installation Connecting Devices to the MDI/MDI-X Ports The last port of the hub (Port 8, Port 12, Port 16 or Port 24) has an associated MDI/MDI-X switch that changes the port from MDI to MDI-X, and vice versa. Connect any 10 Mbps or 100 Mbps device to the port with a straight-through cable and use the following settings: ! Push the switch or MDI) and cascade to a switch or another...
  • Page 27: Chapter 3 Troubleshooting

    Chapter 3 Troubleshooting This chapter provides information to help you resolve problems you might encounter while using the hubs. Contacting Allied Telesyn’s Technical Support If you are unable to fix any problems with the hub after trying the procedures in this chapter, contact Allied Telesyn’s technical support department.
  • Page 28: Diagnosing Hub Indicators

    Troubleshooting ! Verify that the workstation’s adapter card is functioning properly by installing it in another workstation that has been successfully connected to the network. ! Make sure all hubs cascaded together are powered up. Diagnosing Hub Indicators You can easily monitor the hub through its front panel indicators. This section describes common problems you may encounter and possible solutions.
  • Page 29: Product Specifications For The At-Fh700 Series Hubs

    MDI/MDI-X switch Hub Stacking 6 hubs per stack via stacking cables Integrated Switch Module For 10 Mbps and 100 Mbps segment AT-FH708SW, AT-FH712SW, communication; 10/100 Mbps rate adoption and AT-FH716SW and packet filtering between the two collision AT-FH724SW domains; store and forward mode...
  • Page 30 Product Specifications for the AT-FH700 Series Hubs Physical Specifications Dimensions 330 x 204 x 44 mm (13 x 8 x 1.72 in) Weight 2.1 kg (4.6 lb) Electrical Specifications Input line frequency 50-60 Hz Input voltage 100-240 VAC AC Power consumption 100-240 VAC, 50/60 Hz, 0.5A Environmental Specifications Operating temperature...
  • Page 31: Technical Support Fax Order

    Appendix B Technical Support Fax Order Name ___________________________________________________________________ Company ________________________________________________________________ Address _________________________________________________________________ City ________________________State/Province ________________________________ Zip/Postal Code ___________________ Country _________________________________ Phone _______________________________Fax _________________________________ Incident Summary Model number of Allied Telesyn product I am using ______________________________ Network software products I am using _________________________________________ ________________________________________________________________ Brief summary of problem __________________________________________________ ________________________________________________________________...
  • Page 33: At-Fh700 Series Hubs Installation Guide Feedbac

    Appendix C AT-FH700 Series Hubs Installation Guid Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn.
  • Page 35: Appendix D Where To Find Us

    Appendix D Where To Find Us For Technical Support or Service Location Phone Americas 1 (800) 428-4835 1 (918) 628-3222 United States, Canada, Mexico, Central America, South America (+65) 3815-613 (+65) 3833-830 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India Australia (+61) 2-943-5111 (+61) 2-9438-4966...

This manual is also suitable for:

At-fh712swAt-fh716At-fh716swAt-fh724sw

Table of Contents