Troubleshooting - Martin RUSH Club Smoke Dual User Manual

Table of Contents

Advertisement

Troubleshooting

Problem
System will not produce
fog/haze when control panel
set to RUN or remote
control Fog/Haze switch
turned on
System can be fired from
control panel or remote
control, but not by DMX
controller
All fog/haze outputs are
weak
Fog/haze output is weak on
one particular head
Wet, greasy, non-uniform
fog output, fluid drips or
spits from nozzle, or very
loud noise when firing
system
System appears dead
System causes DMX errors
to occur on other units when
connected to a DMX system
26
Probable cause(s)
System not at operating
temperature
 or  set to 0
 set to 0
DMX signal present
DMX address setting
incorrect
Poor connection in DMX
line
LINK menu is set to SEND
Base pump unit requires
priming
Channel requires priming
Incompatible effect fluid
Mains fuse blown
No power at AC cable inlet
LINK menu is set to SEND
Troubleshooting
Suggested remedy
Wait until  message
no longer shown
Increase setting
Increase setting
Disconnect or turn off DMX
controller
Change DMX address
(page 18)
Check DMX cables and
connections
Set LINK menu to RECV
Prime base pump unit (page
18)
Prime the channel (page
18)
Use approved fluid!
Replace fuse (page 25)
Check power cable and
circuit breaker
Set LINK menu to RECV

Advertisement

Table of Contents
loading

Table of Contents