Checking The Package Contents; Product Overview - Kikusui PBZ20-80 SR Setup Manual

Large-capacity bipolar power supply, smart rack system, pbz-sr series, 1,2/1,6/2 kw model
Table of Contents

Advertisement

Checking the Package Contents

When you receive the product, check that all accessories are
included and that the accessories have not been damaged
during transportation.
If any of the accessories are damaged or missing, contact
your Kikusui agent or distributor.
We recommend that all packing materials be saved, in case
the product needs to be transported at a later date.
Pins (30 pcs.)
[84-49-0100]
J1 connector kit (1 set)
CD-ROM (1 pc.)
Quick Reference
English:1 pc., Japanese:1 pc.
Setup guide
(This manual, 1 pc.)
Safety information (1 pc.)

Product Overview

The PBZ-SR series is a large-capacity bipolar regulated DC
power supply. It is a large-current model consisting of PBZ
series bipolar power supplies that are mounted using
dedicated rack parts (smart rack).
• It supports four-quadrant output, which means that it can
source and sink both positive and negative voltages and
currents.
• The internal AC signal or an external signal can be superim-
posed on the DC output.
• You can use the sequence feature to generate test signals
for automotive and other electronic devices.
• Additionally, the PBZ-SR can be used with a variety of loads
to perform tests such as motor endurance tests, solenoid
operation tests, and capacitor ripple tests.
• You can control the PBZ-SR series externally using external
analog signals and control it remotely using RS232C, GPIB,
USB, and LAN communication features.
PBZ-SR
Socket (1 pc.)
[84-49-0160]
Protection cover (2 sets)
[84-49-0161]
If necessary, attach
to the product.
Heavy object warning
label (1 pc.)
[A8-900-158]
Option
The PBZ-SR has the following options. For information about
options, contact your Kikusui agent or distributor.
• AC Input power cable (AC8-3P3M-M5C)
8sq Heavy PVC jacketed three-core cable 3 m
• Low Inductance Cable (TL02-PLZ, TL03-PLZ)
When you connect the cable to the output terminal block of
the PBZ-SR, be sure to provide grounding through the
terminal.
TL02-PLZ
*1
1000 mm
Full length
*2
150 nH
Inductance value
Maximum allowable
current
*1.
Between the insulation caps
*2.
at 100 kHz
• Low Inductance Cable
(LIC40-2P1M-M6M6, LIC40-2P2M-M6M6)
When you connect the cable to the output terminal block of
the PBZ-SR, be sure to provide grounding through the
terminal.
LIC40-2P1M-
M6M6
*1
1000 mm
Full length
*2
150 nH
Inductance value
Maximum allowable
current
*1.
Between the insulation caps
*2.
at 100 kHz
Precautions for Installation
When installing this product, be sure to observe the
precautions provided in "Precautions Concerning Installation
Location" in the Safety information manual. Items specific to
this product are given below.
• Avoid locations where the product is exposed to high tem-
perature or direct sunlight.
Do not install the product near a heater or in areas subject
to drastic temperature changes.
Operating temperature range: 0
Storage temperature range: -25
• Avoid humid environments.
Do not install the product in high-humidity locations–near a
boiler, humidifier, or water supply.
Operating humidity range: 20 %rh to 85 %rh (no condensation)
Storage humidity range: 90 %rh or less (no condensation)
Condensation may occur even within the operating relative
humidity range. If this happens, do not use the product until
the condensation dries up completely.
• The PBZ-SR series does not allow individual PBZs to be
operated separately. Using them separately is outside the
scope of the warranty.
TL03-PLZ
2000 mm
200 nH
100 A
LIC40-2P2M-
M6M6
2000 mm
200 nH
50 A
°
°
°
°
C to +40
C (32
F to +104
F)
°
°
°
°
C to +70
C (-13
F to +158
F)
3

Advertisement

Table of Contents
loading

Table of Contents