Before installation and commissioning

Utilisation for in-
The power source may only be used for MIG/MAG and MMA welding.
tended purpose
Any other form of usage is deemed "not in accordance with the intended purpose".
only
The manufacturer shall not be held liable for any damages arising from such usage.
Utilisation in accordance with the "intended purpose" also comprises
-
-

Setup regulations

The device is tested to IP 23, meaning:
-
-
The device can be set up and operated outdoors in accordance with degree of protection
IP 23.
Avoid direct wetting (e.g. from rain).
The venting duct is a very important safety feature. When choosing the installation location,
ensure that the cooling air can enter and exit unhindered through the air ducts on the front
and back of the device. Electroconductive metallic dust (e.g. from grinding work) must not
be allowed to get sucked into the device.

Mains connection

The devices are designed to run on the mains voltage shown on the respective rating
plates. If your version of the device does not come with mains cables and plugs ready-fit-
ted, these must be fitted in accordance with national regulations and standards. For details
of fuse protection of the mains lead, please see the Technical Data.
38
following all the information in the operating instructions
carrying out all the specified inspection and servicing work
protection against penetration by solid foreign bodies with diameters > 12 mm (0.49
in.)
protection against water sprayed directly at any angle up to 60° from the vertical
WARNING! If one of these machines topples over or falls it could cause serious
or even fatal injury. Place device on a solid, level surface in such a way that it re-
mains stable.
CAUTION! Electroconductive metallic dust may damage the device. The air filter
is a very important safety feature for achieving IP 23. Always fit the air filter when
operating the device.
NOTE! Inadequately dimensioned electrical installations can cause serious dam-
age. The incoming mains lead and its fuse must be dimensioned to suit the local
power supply. The technical data shown on the rating plate applies.