Before commissioning

Safety

Setup regulations

The device is tested to IP 23 protection, meaning:
-
-
Cooling air
The system must be set up in such a way that cooling air can flow unimpeded through the
slots in the front and rear panels.
Dust
Ensure that any metallic dust, for example from grinding work, is not sucked into the sys-
tem by the fan.
Outdoor operation
The device can be set up and operated outdoors in accordance with IP23 degree of pro-
tection. Direct wetting (e.g. from rain) should be avoided.

Mains connection

The device is designed to run at the mains voltage indicated on the rating plate. The re-
quired fuse protection for the mains supply can be found in the "Technical data" section. If
there is no mains cable or mains plug on your device, fit one that conforms to national
standards.
Generator-pow-
The power source is generator-compatible, provided that the maximum apparent power
ered operation
delivered by the generator is at least 22 kVA.
52
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described until you have thoroughly read and
understood the following documents:
-
these operating instructions
-
all the operating instructions for the system components, especially the safe-
ty rules
WARNING! If one of these devices topples over or falls it could cause serious or
even fatal injury. Place units on a solid, level surface so that they remain stable.
protection against penetration by solid foreign bodies with diameters > 12 mm (0.49
in.)
protection against direct sprays of water at any angle up to 60° from the vertical
NOTE! Inadequately dimensioned electrical installations can cause serious dam-
age. The incoming mains lead and its fuse must be dimensioned to suit the local
power supply. The technical data shown on the rating plate applies.
NOTE! The voltage delivered by the generator must never exceed the upper or
lower limits of the mains voltage tolerance range. Details of the mains voltage tol-
erance are given in the "Technical data" section.