RCF MZ 8060 User Manual page 45

Audio matrix with 8 audio inputs and 6 audio outputs
Table of Contents

Advertisement

<PARAMETER> is the channel number for all "controller types" except for PRST and
must be in the range: 1 to 8 for master/slave audio inputs, 1 to 6 for master/slave audio
output, 1 to 16 for master/slave mute and control groups, 1 to 10 for logic inputs (GPI)
and 1 to 6 for logic outputs (GPO).
For PRST controller type, <PARAMETER> is instead the preset number and must be in
the range 1 to 16.
If command execution succeeds, the device will respond to the above command as
follows:
ACK GET_LABEL <CONTROLLER TYPE> <PARAMETER> <LABEL><CR>
with <LABEL> field containing the requested label string (max. 20 characters long).
EXAMPLE 1
GET_LABEL M_MGRP 15<CR>
Returns mute group 15 of master device label string.
The device will respond to the above command with a string similar to the following:
ACK GET_LABEL M_MGRP 15 FOO BAR<CR>
where FOO BAR is the current label of 15th master mute group.
EXAMPLE 2
GET_LABEL PRST 3<CR>
Returns third preset label string.
EXAMPLE 3
GET_LABEL S_IN 6<CR>
Returns slave device input channel 6 label string.
GET_PRESET
Returns active preset ID.
Command syntax is the following:
GET_PRESET<CR>
If command execution succeeds, the device will respond to the above command as
follows:
ACK GET_PRESET <PRESET NUMBER><CR>
with <PRESET NUMBER> field equal to active preset ID in the range 1 to 16.
SET_PRESET
Recalls and activates the preset corresponding to given ID number.
Command syntax is the following:
SET_PRESET <PARAMETER><CR>
in which <PARAMETER> is the ID number of the preset to load and must be in the
range 1 to 16.
If command execution succeeds, the device will respond to the above command as
follows:
ACK SET_PRESET <PARAMETER><CR>
45

Advertisement

Table of Contents
loading