L Ogic Output ( Gpout ) - RCF MZ 8060 User Manual

Audio matrix with 8 audio inputs and 6 audio outputs
Table of Contents

Advertisement

LOGIC OUTPUT (GPOUT)
LOGIC OUTPUT (GPOUT)
Click GPI/GPO in the main window, then select
GPOUT in the GPI/GPO window.
Six logic outputs are available, of which both the
fifth GPOUT 5 (RL1) and the sixth GPOUT6 (RL2)
have relays.
n
:
,
gPouT 5
oTe
as factory default
the
(rl1)
logic output with relay is assigned to
. t
the device fault indication
o enable its user
,
software control
it is necessary to set the
JmP1
(
internal jumper
see the respective
).
manual section
Each logic output includes the following parameters:
Function: selection of the function assigned to the logic output (read the next
paragraph).
ChannelID: parameter depending on the selected FUNCTION, it can be either a preset,
an audio input / output or a MUTE group.
GPOUT 1, 2, 3, 4
Normally High: the logic output is normally high (5 V) and will switch to low
(0) when activated.
Normally Low: the logic output is normally low (0) and will switch to high
(5 V) when activated.
GPOUT 5, 6 (RL1, RL2)
Normally Open: the internal relay contacts are normally open and will get
shorted as soon as the logic output is activated.
Normally Closed: the internal relay contacts are normally closed (shorted) and
will get open as soon as the logic output is activated.
Enable: toggles the logic output (keep it on when using).
38

Advertisement

Table of Contents
loading