And Jmp2 Jumper Settings; Internal Jmp1 ( For Rl1 Logic Output ) And Jmp2 Jumper Settings - RCF MZ 8060 User Manual

Audio matrix with 8 audio inputs and 6 audio outputs
Table of Contents

Advertisement

IMPORTANT: internal jumper settings shall be carried out only by either RCF
or an authorised service centre.
As default, the RL1 logic output with relay is assigned to the device fault indication.
Set the JMP1 internal jumper (on the digital board) to the position 1-2, in order to
enable the user software control.
JUMPER
POSITION
1-2
JMP1
2-3
1-2
JMP2
2-3
INTERNAL JMP1 (for RL1 logic output)

AND JMP2 JUMPER SETTINGS

FUNCTION
The RL1 logic output is software controlled.
The RL1 logic output is assigned to the device fault indication (factory default).
A device fault mutes all audio outputs (factory default).
A device fault does NOT mute all audio outputs.
41