RCF MZ 8060 User Manual page 40

Audio matrix with 8 audio inputs and 6 audio outputs
Table of Contents

Advertisement

The AC RDNET IN/OUT PLUG optional board allows the MZ 8060 remote automixer
control via RDNET.
Refer to the RDNET CONTROL 8 manual about the complete RDNET software use and
further information.
1. Unplug the power cord.
2. Remove the blank panel on the side of the input for
the power cord
22
unscrewing the 4 screws with a TORX T10 screwdriver.
3. Connect the flat cable inside the MZ 8060 automixer to
the AC RDNET IN/OUT PLUG board.
4. Insert the AC RDNET IN/OUT PLUG board into the
MZ 8060 automixer slot and fasten it with the 4
screws.
Each of the eight RDNET CONTROL 8 ports can be connected to max. 32 (daisy-chained)
compatible audio devices.
Each RDNET CONTROL 8 port shall be connected to the DATA INPUT of a RDNET
device and the DATA LINK parallel output to the DATA INPUT of the next device.
RDNET
CONTROL 8
In the example above, [n] is a number from 3 to 32 (max. number of audio devices
connected to a subnet).
The total CAT5 cable length of a single subnet cannot exceed 900 metres (c. 2950 feet).
40
(on the MZ 8060 rear panel) by
DATA IN
DATA LINK
[1]
AC RDNET IN/OUT PLUG BOARD
DATA IN
DATA LINK
[2]
INSTALLATION
DATA IN
DATA LINK
[n]