Logic Inputs And Outputs, Master Unit Only); Logic Inputs (Gpin) - RCF MZ 8060 User Manual

Audio matrix with 8 audio inputs and 6 audio outputs
Table of Contents

Advertisement

GPI/GPO (LOGIC INPUTS AND OUTPUTS, MASTER UNIT ONLY)

LOGIC INPUTS (GPIN)

In the MASTER unit only, it is possible to set up to 10 logic inputs (GPIN), 4 logic outputs
(GPOUT 1 – 4) plus 2 (GPOUT5 and GPOUT6, marked as RL1, RL2 on the rear panel)
with relay.
Click GPI/GPO in the main window.
LOGIC INPUTS (GPIN)
The GPIN screen page allows to set
up to 10 logic inputs.
Each logic input includes the following parameters:
Function: selection of the function assigned to the logic input (read the next
paragraph).
ChannelID: parameter depending on the selected FUNCTION, it can be either a
preset or an audio input / output or a group.
Momentary: the selected function is applied only when the logic input is kept activated.
Toggle: every logic input activation toggles the selected function.
Normally Open: the logic input is activated when its contacts are shorted (or off when
its contacts are open).
Normally Closed: the logic input is activated when its contacts are open (or off when
its contacts are shorted).
SLIDER: allows to adjust the signal level.
Enable: toggles the logic input (keep it on when used).