Warning Messages And Causes; Check Engine Oil Level; Engine Oil Replacement; Low Fuel Level - Telair TIG 3000G Use And Maintenance Manual

Table of Contents

Advertisement

1
Start-up failed
2
Battery voltage too low
3
Motor over-revving
4
Oil level or pressure
5
Motor over-heating
9
Data connection to inverter lost
50
Short circuit on inverter output
51
Overload on inverter output
52
Inverter voltage too low
53
Inverter over-heating
57
An inverter input phase is missing
59
Inverter continuous voltage too high

8.10 Warning messages and causes

8.10.1 Check engine oil level

this message appears alter-
nately with the normal messages on the display
and is highlighted by the illumination of the red
LED (Fig. 30 ref. 7); it calls for the oil level to be
checked (and topped up if necessary).
Once the check has been completed, reset the
corresponding hour counter:
press the MENU button and the following mes-
sage will appear
Press the MENU button again to confirm reset-
ting of the hour counter. The following message
will appear
the red LED switches off (Fig. 30 ref. 7) and the
related message disappears from the display.

8.10.2 Engine oil replacement

this message appears alter-
nately with the normal messages on the display
and is highlighted by the illumination of the red
LED (Fig.30 ref.7); it calls for the engine oil to be
changed.
After completing the operation reset the corre-
sponding hour counter:
press the MENU button and the following mes-
sage will appear
22
GB
Press the MENU button again to confirm zeroing
of the hour counter. The following message will
appear
the red LED switches off (Fig. 30 ref. 7) and the
related message disappears from the display.

8.10.3 Low fuel level

another part of the manual has been performed,
this message indicates that the fuel has reached
the minimum reserve level, and the maintenance
LED lights up (Fig. 30 ref. 7). The generator will
continue to operate until the fuel runs out.

8.10.4 Stop with D+ signal

another part of the manual has been performed,
this message indicates that the generator has
stopped due to a change in status of the D+ sig-
nal received from the vehicle.
To restart it, press the START/STOP button on
the control panel.
TIG 3000 G
if the connection described in
if the connection described in
Vers. 001