6.5 Control and alarm functions (Fig. 30)
2 Display: when the generating set has started
up, the total running hours will be displayed.
Press the key provided below the control panel
display unit (Fig.30 Ref.9) to display the number
of generating set operation hours since the latest
engine oil change.
3 High temperature indicator: this warning light
will light up when the temperature of the
generating set goes over its safety value; the
engine will stop at the same time.
4 Engine oil minimum level indicator: this
warning light will light up to indicate that oil in the
engine has gone below the minimum level. A
safety system will kill the engine automatically to
prevent failures.
5 Engine startup failed: this warning light will
light up to indicate that the generating set has not
started up, after all four start-up attempts.
7 Change oil: this warning light will light up when
the engine has reached 100 running hours since
the latest oil change. Every time the oil is
changed, the After-sales service staff must reset
the timer to zero.
8 Fuel warning: this warning light will light up
when the fuel level inside the extra tank has gone
below its reserve level (about 4 litres)
9 Display time changeover switch: press this
switch to display the running hours since the
latest engine oil change.
10 Reset: When the display shows characters
without any apparent logic, the panel needs to be
reinitialised. Press the Reset key (Fig.30 Ref. 10)
and, holding it down, switch on the panel. When
4 zeroes (0000) are displayed, the panel has
been reinitialised.

6.6 Control panel alarm causes and resetting

During generating set use, alarm signals may be
displayed referring to engine oil checks. After
checking the engine oil, the control panel must
be reset in the following way:
Alarm: the red 'service' light is flashing.
Cause: 50 hours have elapsed since the latest
engine oil change and oil level should be
checked.
How to reset the alarm: press the partial
counter key (Fig.30 Ref.9) and while holding it
down, turn the panel on and release the push-
button when the unit has started up
Alarm: the red 'service' light is lit.
Vers. 001
GB
Cause: 100 hours have elapsed since the latest
engine oil change and engine oil should be
changed.
How to reset the alarm: turn on the panel and
wait for the generating set to start. Now press the
button hidden under the small hole in the bottom
left corner (Fig.30 Ref.10) and release it
immediately thereafter.
Wait a couple of minutes before turning the
generating set off.
In certain situations, the data contained in the
microprocessor inside the panel may be altered.
This may be because the battery is very low, or
because the cables used to connect the battery
to the set have too small cross-sections. Altered
processor data may prevent the generating set
from running. In order to restore the generating
set operating efficiency, proceed as follows:
Alarm:
the
characters.
Cause: malfunctioning due to low voltage during
start-up (low battery, cable cross-section too
small). Reinitialise the panel.
How to reset the control panel: press the
button (Fig.30 Ref. 10) and while holding it down,
turn on the control panel. Only release the push-
button when 4 zeros (0000) are displayed. The
panel has been reinitialised.

6.7 Automatic Version (optional)

If you wish the start-up batteries to be recharged
automatically in the En 2510 G generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig.32) instead of the manual
control panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
Energy 2510 G
display
unit
shows
random
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents