Boost Function; Alarm Messages And Causes; Over Load; Short Circuit - Telair TIG 3000G Use And Maintenance Manual

Table of Contents

Advertisement

the generator will start and it will stop when the
contact is opened.
Should any high-level alarms come from
the generator, such as oil or temperature, the
signal from the D+ input, or pressing the
START/STOP button on the control panel will
take priority over the REMOTE On-Off command.
The oil alarm and the D+ signal prevent remote
start-up until the START/STOP button on the
control panel has been pressed.

8.8 BOOST Function

The BOOST function must be activated when a
single load close to the maximum power must be
connected.
To activate this function, hold down the Menu key
for 3 seconds; the corresponding LED lights up
and even in the absence of any load the engine
increases its rpm.
To turn off the function, press and hold the Menu
key again for 3 seconds; the corresponding LED
will go off and the engine rpm slows down.

8.9 Alarm messages and causes

The alarms described here stop the generator.
An alarm condition is cancelled by pressing the
START/STOP button once; the generator then
reverts to a status in which it can be restarted.
Before doing this, you must eliminate the condi-
tion that caused the stop and the alarm.

8.9.1 Over load

permitted load has been exceeded, the generator
stops and the red alarm LED lights up (Fig.30 ref.
8).

8.9.2 Short circuit

short circuit on 230 V output, the generator stops,
the red alarm LED lights up (Fig.30 ref. 8).
Vers. 001
GB

8.9.3 Low output voltage

voltage has dropped too far below the minimum
limit, probably due to poor performance of the in-
ternal combustion engine or to a single very high
load being applied without the use of the BOOST
function, the generator stops, the red alarm LED
lights up (Fig. 30 ref. 8).

8.9.4 Oil pressure

engine oil lubricant level or pressure has been
detected, the generator immediately stops and
the red alarm LED lights up.

8.9.5 Engine temperature too high

sive engine temperature has been detected, the
generator immediately stops and the red alarm
LED lights up.

8.9.6 Data communications error

there has been an error in communication be-
tween the control panel and the control board on
the generator. Check the connection. Obviously
this alarm cannot be cancelled merely by press-
ing the START/STOP button.
the maximum

8.9.7 Error codes

Open the menu (as indicated in another part of
the manual) until the following text appears
By pressing BOOST and then START/STOP or
there is a
AUTO, the error codes of the last 10 recorded
alarm events can be viewed. This is the list of the
main alarm codes:
TIG 3000 G
the output
insufficient
an exces-
this message indicates that
21